Industrial Power Switching · RTX-TOR36
RTX-TOR36 Thermal Overload Relays 1A-160A
Adjustable thermal overload relays for three-phase motor protection, with 13 setting bands from 1A to 160A across three frame sizes.
Setting range1A–160A, 13 bands
JänniteUp to 690V
AsetuksetFrame mapping to confirm
SertifiointiCCC
Tuotekatsaus
RTX-TOR36 relays pair with contactors to trip a motor circuit on sustained overload. Each band has an adjustable current dial. Choose the band so the motor full-load current sits within the setting range.
Tärkeimmät ominaisuudet
- 13 adjustable current bands
- Frame mapping confirmed at order
- Rated up to 690V
- CCC supplier-listed
Saatavilla olevat mallit / kokoonpanot
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS-viite | Setting range | Asetukset |
|---|---|---|
| RTX-TOR36-1-16 | 1–1.6 A | Confirm with RITOKS before ordering |
| RTX-TOR36-15-24 | 1.5–2.4 A | Confirm with RITOKS before ordering |
| RTX-TOR36-22-35 | 2.2–3.5 A | Confirm with RITOKS before ordering |
| RTX-TOR36-32-5 | 3.2–5 A | Confirm with RITOKS before ordering |
| RTX-TOR36-45-72 | 4.5–7.2 A | Confirm with RITOKS before ordering |
| RTX-TOR36-68-11 | 6.8–11 A | Confirm with RITOKS before ordering |
| RTX-TOR36-10-16 | 10–16 A | Confirm with RITOKS before ordering |
| RTX-TOR36-14-22 | 14–22 A | Confirm with RITOKS before ordering |
| RTX-TOR36-28-45 | 28–45 A | Confirm with RITOKS before ordering |
| RTX-TOR36-40-63 | 40–63 A | Confirm with RITOKS before ordering |
| RTX-TOR36-53-85 | 53–85 A | Confirm with RITOKS before ordering |
| RTX-TOR36-75-120 | 75–120 A | Confirm with RITOKS before ordering |
| RTX-TOR36-100-160 | 100–160 A | Confirm with RITOKS before ordering |
Tekniset tiedot
| Tuotetyyppi | Lämpöylikuormitusrele |
|---|---|
| Setting bands | 1–1.6, 1.5–2.4, 2.2–3.5, 3.2–5, 4.5–7.2, 6.8–11, 10–16, 14–22, 28–45, 40–63, 53–85, 75–120, 100–160 A |
| Frame mapping | Not published; confirm with ritoks before ordering |
| Nimellisjännite | Up to 690V |
| Sertifiointi | CCC (supplier-listed) |
| Trip class and auxiliary contacts | Not published; confirm with ritoks before ordering |
Sovellukset
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Motor starter panels
Combine with an AC contactor to build direct-on-line starters.
Compressor and pump motors
Protect three-phase motors against sustained overload.
Conveyor drives
Set the dial to motor full-load current on each conveyor drive.
Valintaa varten vahvistettavat tiedot
- Moottorin täyskuormavirta
- Contactor model and mounting
- Trip class and reset mode
- Auxiliary contact and quantity needs
Usein kysytyt kysymykset
How do I choose a setting band?
Choose a band whose range contains the motor full-load current, then set the dial to that value.
Which contactors does it fit?
Mounting compatibility is not published. Confirm the contactor model before ordering.
Pyydä tarjous
Ilmoittakaa tarkka malli, vaaditut nimellisarvot, määrä ja toimituskohde. Tarkistamme saatavuuden ja asiakirjat ennen tarjouksen antamista.