Current Shunts · RTX-FL15
RTX-FL15 US-Style DC Current Shunts 5A-600A, 50/75/100mV
US-style DC current shunts from 5A to 600A, each available with 50mV, 75mV or 100mV output and ±0.25% resistance tolerance.
Courant nominal5A–600A
Résultat50 / 75 / 100mV
Tolerance±0.25%
Ratings14 current ratings
Présentation du produit
RTX-FL15 shunts convert DC current into a low millivolt signal for panel meters, battery monitors and data loggers. Each current rating is offered at three full-scale outputs, so the shunt can match the input range of the meter instead of the meter being chosen around the shunt. Resistance follows Ohm's law, for example 0.75mΩ for 100A at 75mV.
Caractéristiques principales
- Fourteen ratings from 5A to 600A
- 50mV, 75mV and 100mV outputs for each rating
- ±0.25% resistance tolerance
- US-style shunt construction
Modèles / configurations disponibles
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Référence RITOKS | Courant nominal | 50mV resistance | 75mV resistance | 100mV resistance |
|---|---|---|---|---|
| RTX-FL15-5 | 5A | 10 mΩ | 15 mΩ | 20 mΩ |
| RTX-FL15-10 | 10A | 5 mΩ | 7.5 mΩ | 10 mΩ |
| RTX-FL15-15 | 15A | 3.3333 mΩ | 5 mΩ | 6.666 mΩ |
| RTX-FL15-20 | 20 A | 2.5 mΩ | 3.75 mΩ | 5 mΩ |
| RTX-FL15-30 | 30 A | 1.6666 mΩ | 2.5 mΩ | 3.33 mΩ |
| RTX-FL15-50 | 50 A | 1 mΩ | 1.5 mΩ | 2 mΩ |
| RTX-FL15-75 | 75 A | 0.6666 mΩ | 1 mΩ | 1.33 mΩ |
| RTX-FL15-100 | 100 A | 0.5 mΩ | 0.75 mΩ | 1 mΩ |
| RTX-FL15-150 | 150 A | 0.333333 mΩ | 0.5 mΩ | 0.666 mΩ |
| RTX-FL15-200 | 200 A | 0.25 mΩ | 0.375 mΩ | 0.5 mΩ |
| RTX-FL15-300 | 300 A | 0.166667 mΩ | 0.25 mΩ | 0.333333 mΩ |
| RTX-FL15-400 | 400 A | 0.125 mΩ | 0.1875 mΩ | 0.25 mΩ |
| RTX-FL15-500 | 500 A | 0.1 mΩ | 0.15 mΩ | 0.2 mΩ |
| RTX-FL15-600 | 600 A | 0.083333 mΩ | 0.125 mΩ | 0.166667 mΩ |
Caractéristiques techniques
| Type de produit | DC current shunt, US-style |
|---|---|
| Courant nominal | 5A, 10A, 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 500A, 600A |
| Puissance nominale | 50mV, 75mV or 100mV |
| Resistance tolerance | ±0.25% |
| Résistance | Nominal values calculated as R = V/I from rated output and current; repeating decimals are rounded. These values do not represent measured resistance or change the specified resistance tolerance |
| Continuous load derating and temperature coefficient | Confirm with RITOKS before ordering |
| Dimensions | Confirm with RITOKS before ordering |
Applications
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Battery chargers and test benches
Measure charge and discharge current with a millivolt panel ammeter on the cabinet door.
Solar and battery monitors
Feed a battery monitor or energy meter that expects a 50mV, 75mV or 100mV shunt input.
Alimentations en courant continu
Monitor output current of rectifiers and DC supplies in telecom and process equipment.
Informations à vérifier pour la sélection
- Maximum continuous DC current
- Meter or monitor input: 50mV, 75mV or 100mV
- Required accuracy and operating temperature
- Terminal and bolt size, and quantity
FAQ
How is the shunt resistance calculated?
Divide the rated output voltage by the rated current. For example 75mV divided by 100A gives 0.75mΩ.
Can a shunt run continuously at full rating?
Continuous-load derating is not published for this series. Many installations size the shunt above the normal current; confirm with RITOKS.
Demander un devis
Veuillez nous indiquer le modèle exact, les puissances nominales requises, la quantité et la destination. Nous vérifierons la disponibilité et les documents nécessaires avant de vous établir un devis.