US-style DC current shunts from 5A to 600A, each available with 50mV, 75mV or 100mV output and ±0.25% resistance tolerance.

Märkström5A–600A

Utdata50 / 75 / 100mV

Tolerance±0.25%

Ratings14 current ratings

Produktöversikt

RTX-FL15 shunts convert DC current into a low millivolt signal for panel meters, battery monitors and data loggers. Each current rating is offered at three full-scale outputs, so the shunt can match the input range of the meter instead of the meter being chosen around the shunt. Resistance follows Ohm's law, for example 0.75mΩ for 100A at 75mV.

Viktiga funktioner

  • Fourteen ratings from 5A to 600A
  • 50mV, 75mV and 100mV outputs for each rating
  • ±0.25% resistance tolerance
  • US-style shunt construction

Tillgängliga modeller / konfigurationer

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS-referensMärkström50mV resistance75mV resistance100mV resistance
RTX-FL15-55A10 mΩ15 mΩ20 mΩ
RTX-FL15-1010A5 mΩ7.5 mΩ10 mΩ
RTX-FL15-1515A3.3333 mΩ5 mΩ6.666 mΩ
RTX-FL15-2020A2.5 mΩ3.75 mΩ5 mΩ
RTX-FL15-3030A1.6666 mΩ2.5 mΩ3.33 mΩ
RTX-FL15-5050A1 mΩ1.5 mΩ2 mΩ
RTX-FL15-7575A0.6666 mΩ1 mΩ1.33 mΩ
RTX-FL15-100100A0.5 mΩ0.75 mΩ1 mΩ
RTX-FL15-150150A0.333333 mΩ0.5 mΩ0.666 mΩ
RTX-FL15-200200A0.25 mΩ0.375 mΩ0.5 mΩ
RTX-FL15-300300A0.166667 mΩ0.25 mΩ0.333333 mΩ
RTX-FL15-400400A0.125 mΩ0.1875 mΩ0.25 mΩ
RTX-FL15-500500A0.1 mΩ0.15 mΩ0.2 mΩ
RTX-FL15-600600A0.083333 mΩ0.125 mΩ0.166667 mΩ

Tekniska specifikationer

ProdukttypDC current shunt, US-style
Märkström5A, 10A, 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 500A, 600A
Nominell effekt50mV, 75mV or 100mV
Resistance tolerance±0.25%
MotståndNominal values calculated as R = V/I from rated output and current; repeating decimals are rounded. These values do not represent measured resistance or change the specified resistance tolerance
Continuous load derating and temperature coefficientConfirm with RITOKS before ordering
MåttConfirm with RITOKS before ordering

Ansökningar

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a DC current shunt wired to a panel ammeter inside a battery charger test cabinet

Battery chargers and test benches

Measure charge and discharge current with a millivolt panel ammeter on the cabinet door.

Solar and battery monitors

Feed a battery monitor or energy meter that expects a 50mV, 75mV or 100mV shunt input.

Likströmsförsörjningar

Monitor output current of rectifiers and DC supplies in telecom and process equipment.

Uppgifter som måste bekräftas inför urvalet

  • Maximum continuous DC current
  • Meter or monitor input: 50mV, 75mV or 100mV
  • Required accuracy and operating temperature
  • Terminal and bolt size, and quantity

Vanliga frågor

How is the shunt resistance calculated?

Divide the rated output voltage by the rated current. For example 75mV divided by 100A gives 0.75mΩ.

Can a shunt run continuously at full rating?

Continuous-load derating is not published for this series. Many installations size the shunt above the normal current; confirm with RITOKS.

Begär en offert

Ange exakt modell, önskade prestandavärden, antal och leveransadress. Vi bekräftar tillgänglighet och dokumentation innan vi lämnar en offert.

Begär produktinformation och priser

Skicka modellnummer, prestandavärden, antal och uppgifter om leveransadress. Vi bekräftar tillgängligheten innan vi tar fram en offert.

Bläddra till toppen