US-style DC current shunts from 5A to 600A, each available with 50mV, 75mV or 100mV output and ±0.25% resistance tolerance.

Courant nominal5A–600A

Résultat50 / 75 / 100mV

Tolerance±0.25%

Ratings14 current ratings

Présentation du produit

RTX-FL15 shunts convert DC current into a low millivolt signal for panel meters, battery monitors and data loggers. Each current rating is offered at three full-scale outputs, so the shunt can match the input range of the meter instead of the meter being chosen around the shunt. Resistance follows Ohm's law, for example 0.75mΩ for 100A at 75mV.

Caractéristiques principales

  • Fourteen ratings from 5A to 600A
  • 50mV, 75mV and 100mV outputs for each rating
  • ±0.25% resistance tolerance
  • US-style shunt construction

Modèles / configurations disponibles

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Référence RITOKSCourant nominal50mV resistance75mV resistance100mV resistance
RTX-FL15-55A10 mΩ15 mΩ20 mΩ
RTX-FL15-1010A5 mΩ7.5 mΩ10 mΩ
RTX-FL15-1515A3.3333 mΩ5 mΩ6.666 mΩ
RTX-FL15-2020 A2.5 mΩ3.75 mΩ5 mΩ
RTX-FL15-3030 A1.6666 mΩ2.5 mΩ3.33 mΩ
RTX-FL15-5050 A1 mΩ1.5 mΩ2 mΩ
RTX-FL15-7575 A0.6666 mΩ1 mΩ1.33 mΩ
RTX-FL15-100100 A0.5 mΩ0.75 mΩ1 mΩ
RTX-FL15-150150 A0.333333 mΩ0.5 mΩ0.666 mΩ
RTX-FL15-200200 A0.25 mΩ0.375 mΩ0.5 mΩ
RTX-FL15-300300 A0.166667 mΩ0.25 mΩ0.333333 mΩ
RTX-FL15-400400 A0.125 mΩ0.1875 mΩ0.25 mΩ
RTX-FL15-500500 A0.1 mΩ0.15 mΩ0.2 mΩ
RTX-FL15-600600 A0.083333 mΩ0.125 mΩ0.166667 mΩ

Caractéristiques techniques

Type de produitDC current shunt, US-style
Courant nominal5A, 10A, 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 500A, 600A
Puissance nominale50mV, 75mV or 100mV
Resistance tolerance±0.25%
RésistanceNominal values calculated as R = V/I from rated output and current; repeating decimals are rounded. These values do not represent measured resistance or change the specified resistance tolerance
Continuous load derating and temperature coefficientConfirm with RITOKS before ordering
DimensionsConfirm with RITOKS before ordering

Applications

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a DC current shunt wired to a panel ammeter inside a battery charger test cabinet

Battery chargers and test benches

Measure charge and discharge current with a millivolt panel ammeter on the cabinet door.

Solar and battery monitors

Feed a battery monitor or energy meter that expects a 50mV, 75mV or 100mV shunt input.

Alimentations en courant continu

Monitor output current of rectifiers and DC supplies in telecom and process equipment.

Informations à vérifier pour la sélection

  • Maximum continuous DC current
  • Meter or monitor input: 50mV, 75mV or 100mV
  • Required accuracy and operating temperature
  • Terminal and bolt size, and quantity

FAQ

How is the shunt resistance calculated?

Divide the rated output voltage by the rated current. For example 75mV divided by 100A gives 0.75mΩ.

Can a shunt run continuously at full rating?

Continuous-load derating is not published for this series. Many installations size the shunt above the normal current; confirm with RITOKS.

Demander un devis

Veuillez nous indiquer le modèle exact, les puissances nominales requises, la quantité et la destination. Nous vérifierons la disponibilité et les documents nécessaires avant de vous établir un devis.

Demander des informations sur les produits et les tarifs

Veuillez nous communiquer les références des modèles, les puissances nominales, les quantités et les informations relatives à la destination. Nous vérifierons la disponibilité avant de vous établir un devis.

Retour en haut de la page