अभी पूछताछ करें
RITOKS RTX-DIT19 DC current and voltage isolation transducer on a white background

DC Current Transducers · RTX-DIT19

RTX-DIT19 Direct-Input DC Current and Voltage Isolation Transducers

Isolated transducers that measure DC current up to 10A or DC voltage up to 1000V directly and convert it to a standard analog signal, with 0.2% accuracy.

Current inputDC 0–10A (direct)

Voltage inputDC 0–1000V (direct)

सटीकता0.2%

आउटपुट4–20mA / 0–10V

उत्पाद अवलोकन

RTX-DIT19 converts a DC current or voltage measured directly in the circuit into an isolated standard signal for PLCs, meters and data loggers. Current versions cover inputs up to 10A without an external shunt; voltage versions cover inputs up to 1000V DC. The supplier lists 0.2% accuracy and an enclosure 119 mm long. For larger currents through an external sensor, see WBI334U01-S; for an isolated DC voltage transducer range, see RTX-DVT. Supply voltage, mounting and response time must be confirmed for each configuration.

मुख्य विशेषताएँ

  • Direct DC current input up to 10A
  • Direct DC voltage input up to 1000V
  • 0.2% accuracy listed by the supplier
  • Isolated standard output such as 4–20mA or 0–10V

उपलब्ध मॉडल / विन्यास

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

रिटोक्स संदर्भMeasured quantityइनपुट सीमाआउटपुट
RTX-DIT19-I5DC current0–5A4–20mA / 0–10V
RTX-DIT19-I10DC current0–10A4–20mA / 0–10V
RTX-DIT19-U100डीसी वोल्टेज0–100V4–20mA / 0–10V
RTX-DIT19-U1000डीसी वोल्टेज0–1000V4–20mA / 0–10V

तकनीकी विनिर्देश

उत्पाद का प्रकारIsolated DC current / voltage transducer
Current inputDC 0–10A
Voltage inputDC 0–1000V
सटीकता0.2%
Output signal4–20mA, 0–5V, 0–10V (confirm)
लंबाई119 mm (supplier-listed)
वजनApprox. 0.5 kg (supplier-listed)
सहायक आपूर्तिConfirm with RITOKS before ordering
Isolation voltage and response timeConfirm with RITOKS before ordering

आवेदन

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of DIN-rail DC transducers wired in a battery test bench control cabinet

Battery charging test benches

Measure charging current and battery voltage and send isolated 4–20mA signals to the bench controller.

DC motor and drive monitoring

Monitor armature current and DC bus voltage in DC drives without an external shunt.

Telecom DC power systems

Report rectifier output voltage and load current to the site monitoring unit.

चयन के लिए पुष्टि हेतु जानकारी

  • Measured quantity: DC current or DC voltage
  • इनपुट सीमा
  • आवश्यक आउटपुट संकेत
  • Auxiliary supply voltage and mounting, and quantity

अक्सर पूछे जाने वाले प्रश्न

Do I need a shunt with RTX-DIT19?

No. Current versions measure up to 10A directly. For higher currents, use a shunt or a Hall-effect transducer such as WBI334U01-S.

Can one unit measure both current and voltage?

Each unit is configured for one measured quantity and range. Order a current version and a voltage version if you need both.

कोटेशन का अनुरोध करें

सटीक मॉडल, आवश्यक रेटिंग, मात्रा और गंतव्य भेजें। हम कोटेशन से पहले उपलब्धता और दस्तावेज़ीकरण की पुष्टि करेंगे।.

उत्पाद जानकारी और मूल्य निर्धारण का अनुरोध करें

मॉडल नंबर, रेटिंग, मात्राएँ और गंतव्य विवरण भेजें। हम कोटेशन तैयार करने से पहले उपलब्धता की पुष्टि करेंगे।.