DC Current Transducers · RTX-DIT19
RTX-DIT19 Direct-Input DC Current and Voltage Isolation Transducers
Isolated transducers that measure DC current up to 10A or DC voltage up to 1000V directly and convert it to a standard analog signal, with 0.2% accuracy.
Current inputDC 0–10A (direct)
Voltage inputDC 0–1000V (direct)
Precisão0.2%
Saída4–20mA / 0–10V
Visão geral do produto
RTX-DIT19 converts a DC current or voltage measured directly in the circuit into an isolated standard signal for PLCs, meters and data loggers. Current versions cover inputs up to 10A without an external shunt; voltage versions cover inputs up to 1000V DC. The supplier lists 0.2% accuracy and an enclosure 119 mm long. For larger currents through an external sensor, see WBI334U01-S; for an isolated DC voltage transducer range, see RTX-DVT. Supply voltage, mounting and response time must be confirmed for each configuration.
Principais recursos
- Direct DC current input up to 10A
- Direct DC voltage input up to 1000V
- 0.2% accuracy listed by the supplier
- Isolated standard output such as 4–20mA or 0–10V
Modelos / Configurações disponíveis
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Referência RITOKS | Measured quantity | Intervalo de entrada | Saída |
|---|---|---|---|
| RTX-DIT19-I5 | DC current | 0–5A | 4–20mA / 0–10V |
| RTX-DIT19-I10 | DC current | 0–10A | 4–20mA / 0–10V |
| RTX-DIT19-U100 | Tensão contínua | 0–100V | 4–20mA / 0–10V |
| RTX-DIT19-U1000 | Tensão contínua | 0–1000V | 4–20mA / 0–10V |
Especificações Técnicas
| Tipo de produto | Isolated DC current / voltage transducer |
|---|---|
| Current input | DC 0–10A |
| Voltage input | DC 0–1000V |
| Precisão | 0.2% |
| Output signal | 4–20mA, 0–5V, 0–10V (confirm) |
| Comprimento | 119 mm (supplier-listed) |
| Peso | Approx. 0.5 kg (supplier-listed) |
| Alimentação auxiliar | Confirm with RITOKS before ordering |
| Isolation voltage and response time | Confirm with RITOKS before ordering |
Aplicações
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Battery charging test benches
Measure charging current and battery voltage and send isolated 4–20mA signals to the bench controller.
DC motor and drive monitoring
Monitor armature current and DC bus voltage in DC drives without an external shunt.
Telecom DC power systems
Report rectifier output voltage and load current to the site monitoring unit.
Informações a serem confirmadas para a seleção
- Measured quantity: DC current or DC voltage
- Intervalo de entrada
- Sinal de saída exigido
- Auxiliary supply voltage and mounting, and quantity
Perguntas frequentes
Do I need a shunt with RTX-DIT19?
No. Current versions measure up to 10A directly. For higher currents, use a shunt or a Hall-effect transducer such as WBI334U01-S.
Can one unit measure both current and voltage?
Each unit is configured for one measured quantity and range. Order a current version and a voltage version if you need both.
Solicite um orçamento
Envie o modelo exato, as potências necessárias, a quantidade e o destino. Confirmaremos a disponibilidade e a documentação antes de elaborar o orçamento.