今すぐお問い合わせ
RITOKS RTX-ML250 four-pole residual current molded case circuit breaker on a white background

Molded Case Circuit Breakers · RTX-ML250

RTX-ML250 4P Residual Current Molded Case Circuit Breakers 250A

Four-pole residual current molded case circuit breaker with a 250A frame, rated AC400V and 50kA breaking capacity, combining overcurrent and earth-leakage protection in one device.

Frame current250A

ポール4P

定格電圧AC400V

破断強度50kA

製品概要

RTX-ML250 is a residual current MCCB for three-phase four-wire feeders where earth-leakage protection is needed at the same point as overcurrent protection. The 250A frame and 4P construction suit main incomers and outgoing feeders in industrial, farm and building distribution boards. The supplier lists CQC certification, an all-copper coil and flame-retardant housing material. RITOKS also offers the RTX-M1 and GYCM8 thermal-magnetic MCCB ranges without residual current protection; choose RTX-ML250 when the circuit also needs leakage tripping. Residual operating current and trip-current adjustment must be confirmed for each order.

主な特長

  • Combined overcurrent and residual current protection
  • 250A frame, four-pole construction for 3-phase 4-wire systems
  • AC400V rated voltage, 50kA breaking capacity
  • CQC certification listed by the supplier (certificate CQC22107335603)
  • All-copper coil and flame-retardant housing material

取り扱いモデル/構成

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS リファレンスFrame currentポール定格電圧破断強度
RTX-ML250/4300250A4PAC400V50kA

技術仕様

製品タイプResidual current molded case circuit breaker
Frame current250A
定格電流250A (other trip ratings: confirm)
ポール4P
定格電圧AC400V
破断強度50kA
認証CQC (supplier-listed)
重量Approx. 500 g (supplier-listed)
残留動作電流Selector marked 100 / 300 / 500 mA on the product label (confirm)
Residual trip delaySelector marked 0.1 / 0.3 / 0.5 s on the product label (confirm)
Trip unit characteristicsConfirm with RITOKS before ordering

用途

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a four-pole residual current MCCB installed as the incomer in a factory distribution board

Factory distribution incomers

Protect the incoming feeder of a workshop distribution board against overload, short circuit and earth leakage with a single four-pole device.

Agricultural pump and irrigation feeders

Supply three-phase pump motors in damp outdoor environments, where earth-leakage tripping reduces the risk from damaged cables.

Commercial building sub-boards

Feed floor or tenant sub-distribution boards that require residual current protection at the outgoing feeder.

選考の際に確認すべき情報

  • System voltage, earthing arrangement and number of poles
  • Required rated current and residual operating current
  • Breaking capacity at the installation point
  • Terminal and mounting requirements, and quantity

よくある質問

How is RTX-ML250 different from RTX-M1?

RTX-M1 is a thermal-magnetic MCCB range without earth-leakage tripping. RTX-ML250 adds residual current protection on a 250A four-pole frame.

Which residual operating currents are available?

The product label shows a selector marked 100, 300 and 500 mA, with delay settings of 0.1, 0.3 and 0.5 s. Confirm the required sensitivity with RITOKS before ordering.

お見積りのお申し込み

正確な型番、必要な定格、数量、および配送先をお知らせください。お見積り前に、在庫状況と必要書類について確認させていただきます。.

製品情報および価格のお問い合わせ

型番、定格、数量、および配送先情報をお知らせください。お見積りを作成する前に、在庫状況を確認させていただきます。.

ページの上部へスクロール