Molded Case Circuit Breakers · RTX-ML250
RTX-ML250 4P Residual Current Molded Case Circuit Breakers 250A
Four-pole residual current molded case circuit breaker with a 250A frame, rated AC400V and 50kA breaking capacity, combining overcurrent and earth-leakage protection in one device.
Frame current250 А
Поляки4P
Номінальна напругаAC400V
Руйнівна здатність50kA
Огляд продукту
RTX-ML250 is a residual current MCCB for three-phase four-wire feeders where earth-leakage protection is needed at the same point as overcurrent protection. The 250A frame and 4P construction suit main incomers and outgoing feeders in industrial, farm and building distribution boards. The supplier lists CQC certification, an all-copper coil and flame-retardant housing material. RITOKS also offers the RTX-M1 and GYCM8 thermal-magnetic MCCB ranges without residual current protection; choose RTX-ML250 when the circuit also needs leakage tripping. Residual operating current and trip-current adjustment must be confirmed for each order.
Основні особливості
- Combined overcurrent and residual current protection
- 250A frame, four-pole construction for 3-phase 4-wire systems
- AC400V rated voltage, 50kA breaking capacity
- CQC certification listed by the supplier (certificate CQC22107335603)
- All-copper coil and flame-retardant housing material
Доступні моделі / конфігурації
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Довідка RITOKS | Frame current | Поляки | Номінальна напруга | Руйнівна здатність |
|---|---|---|---|---|
| RTX-ML250/4300 | 250 А | 4P | AC400V | 50kA |
Технічні характеристики
| Тип товару | Residual current molded case circuit breaker |
|---|---|
| Frame current | 250 А |
| Номінальний струм | 250A (other trip ratings: confirm) |
| Поляки | 4P |
| Номінальна напруга | AC400V |
| Руйнівна здатність | 50kA |
| Сертифікація | CQC (supplier-listed) |
| Вага | Approx. 500 g (supplier-listed) |
| Залишковий робочий струм | Selector marked 100 / 300 / 500 mA on the product label (confirm) |
| Residual trip delay | Selector marked 0.1 / 0.3 / 0.5 s on the product label (confirm) |
| Trip unit characteristics | Confirm with RITOKS before ordering |
Застосування
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Factory distribution incomers
Protect the incoming feeder of a workshop distribution board against overload, short circuit and earth leakage with a single four-pole device.
Agricultural pump and irrigation feeders
Supply three-phase pump motors in damp outdoor environments, where earth-leakage tripping reduces the risk from damaged cables.
Commercial building sub-boards
Feed floor or tenant sub-distribution boards that require residual current protection at the outgoing feeder.
Інформація, яку необхідно підтвердити для відбору
- System voltage, earthing arrangement and number of poles
- Required rated current and residual operating current
- Breaking capacity at the installation point
- Terminal and mounting requirements, and quantity
Часті запитання
How is RTX-ML250 different from RTX-M1?
RTX-M1 is a thermal-magnetic MCCB range without earth-leakage tripping. RTX-ML250 adds residual current protection on a 250A four-pole frame.
Which residual operating currents are available?
The product label shows a selector marked 100, 300 and 500 mA, with delay settings of 0.1, 0.3 and 0.5 s. Confirm the required sensitivity with RITOKS before ordering.