Industrial Power Switching · RTX-TOR36
RTX-TOR36 Thermal Overload Relays 1A-160A
Adjustable thermal overload relays for three-phase motor protection, with 13 setting bands from 1A to 160A across three frame sizes.
Setting range1A–160A, 13 bands
전압Up to 690V
구성Frame mapping to confirm
인증CCC
제품 개요
RTX-TOR36 relays pair with contactors to trip a motor circuit on sustained overload. Each band has an adjustable current dial. Choose the band so the motor full-load current sits within the setting range.
주요 기능
- 13 adjustable current bands
- Frame mapping confirmed at order
- Rated up to 690V
- CCC supplier-listed
사용 가능한 모델 / 구성
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS 참조 | Setting range | 구성 |
|---|---|---|
| RTX-TOR36-1-16 | 1–1.6 A | Confirm with RITOKS before ordering |
| RTX-TOR36-15-24 | 1.5–2.4 A | Confirm with RITOKS before ordering |
| RTX-TOR36-22-35 | 2.2–3.5 A | Confirm with RITOKS before ordering |
| RTX-TOR36-32-5 | 3.2–5 A | Confirm with RITOKS before ordering |
| RTX-TOR36-45-72 | 4.5–7.2 A | Confirm with RITOKS before ordering |
| RTX-TOR36-68-11 | 6.8–11 A | Confirm with RITOKS before ordering |
| RTX-TOR36-10-16 | 10–16 A | Confirm with RITOKS before ordering |
| RTX-TOR36-14-22 | 14–22 A | Confirm with RITOKS before ordering |
| RTX-TOR36-28-45 | 28–45 A | Confirm with RITOKS before ordering |
| RTX-TOR36-40-63 | 40–63 A | Confirm with RITOKS before ordering |
| RTX-TOR36-53-85 | 53–85 A | Confirm with RITOKS before ordering |
| RTX-TOR36-75-120 | 75–120 A | Confirm with RITOKS before ordering |
| RTX-TOR36-100-160 | 100–160 A | Confirm with RITOKS before ordering |
기술 사양
| 제품 유형 | 열 과부하 릴레이 |
|---|---|
| Setting bands | 1–1.6, 1.5–2.4, 2.2–3.5, 3.2–5, 4.5–7.2, 6.8–11, 10–16, 14–22, 28–45, 40–63, 53–85, 75–120, 100–160 A |
| Frame mapping | Not published; confirm with ritoks before ordering |
| 정격 전압 | Up to 690V |
| 인증 | CCC (supplier-listed) |
| Trip class and auxiliary contacts | Not published; confirm with ritoks before ordering |
응용 분야
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Motor starter panels
Combine with an AC contactor to build direct-on-line starters.
Compressor and pump motors
Protect three-phase motors against sustained overload.
Conveyor drives
Set the dial to motor full-load current on each conveyor drive.
선정을 위해 확인해야 할 사항
- 모터 정격 부하 전류
- Contactor model and mounting
- Trip class and reset mode
- Auxiliary contact and quantity needs
자주 묻는 질문
How do I choose a setting band?
Choose a band whose range contains the motor full-load current, then set the dial to that value.
Which contactors does it fit?
Mounting compatibility is not published. Confirm the contactor model before ordering.