Hall Effect Current Sensors · RTX-HCL500
RTX-HCL500 Closed-Loop Hall Current Sensors 200A-500A, Current Output
Closed-loop Hall current sensors for 200A, 300A and 500A primary currents with 100mA or 150mA current output and 0.5% listed accuracy, for panel mounting.
Primary current200A / 300A / 500A
Output100mA or 150mA current
Accuracy0.5% (supplier-listed)
TypeClosed-loop Hall
Product Overview
RTX-HCL500 sensors measure current in a conductor passing through the aperture using closed-loop (compensated) Hall technology. The secondary output is a current proportional to the primary current, which can be converted to voltage with a burden resistor at the measuring input. Four configurations cover 200A to 500A with 100mA or 150mA secondary output, at a listed accuracy of 0.5%. Closed-loop designs are typically chosen over open-loop sensors where better linearity and response are required; confirm supply voltage, aperture and response time for the selected configuration.
Key Features
- Closed-loop Hall measurement principle
- 200A, 300A and 500A primary configurations
- 100mA or 150mA secondary current output
- 0.5% accuracy listed by the supplier
Available Models / Configurations
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS reference | Primary current | Secondary output | Output type |
|---|---|---|---|
| RTX-HCL500-200/100 | 200A | 100mA | Current |
| RTX-HCL500-300/150 | 300A | 150mA | Current |
| RTX-HCL500-300/100 | 300A | 100mA | Current |
| RTX-HCL500-500/100 | 500A | 100mA | Current |
Technical Specifications
| Product type | Closed-loop Hall effect current sensor |
|---|---|
| Primary current | 200A, 300A or 500A by model |
| Secondary output | 100mA or 150mA current by model |
| Accuracy | 0.5% (supplier-listed) |
| Mounting | Panel mounting |
| Weight | 230 g (supplier-listed) |
| Supply voltage | Confirm with RITOKS before ordering |
| Aperture size | Confirm with RITOKS before ordering |
| Response time and bandwidth | Confirm with RITOKS before ordering |
| Isolation voltage | Confirm with RITOKS before ordering |
Applications
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Inverter and converter output
Measure phase or DC-link current in drives and inverters where a fast, linear feedback signal is needed for control.
Battery energy storage
Monitor charge and discharge current on battery string busbars with an isolated current-output signal.
UPS and rectifier systems
Supervise rectifier output and battery current in UPS cabinets with long signal runs that benefit from a current output.
Information to Confirm for Selection
- Maximum primary current and whether it is AC, DC or pulsed
- Required secondary output: 100mA or 150mA
- Available supply voltage
- Conductor or busbar size passing through the aperture, and quantity
FAQ
Why choose a closed-loop sensor instead of open-loop?
Closed-loop Hall sensors compensate the magnetic flux in the core, which generally gives better linearity and response than open-loop types. RITOKS also supplies open-loop sensors such as HS2V H02 and RTX-HSC where cost or size matters more.
How do I read the current output?
Pass the secondary current through a burden resistor at your measuring input and read the voltage. Confirm the allowed burden range for the selected model with RITOKS.