Solicite informações agora
RITOKS RTX-ATSC CB-class four-pole automatic transfer switch on a white background

Automatic Transfer Switches · RTX-ATSC

RTX-ATSC CB-Class Automatic Transfer Switches 63A-1600A, 4P

Four-pole CB-class dual-power automatic transfer switches from 63A to 1600A with 30kA breaking capacity, for automatic changeover between mains and backup supply.

Corrente nominal63A–1600A

Pólos4P

ClassCB

Capacidade de ruptura30kA

Visão geral do produto

RTX-ATSC transfers a load automatically between two power sources, such as mains and a generator. As a CB-class transfer switch it is built from two circuit breakers with an interlocked operating mechanism, so it switches between sources and also provides overcurrent protection. The supplier lists eleven frame sizes from 63A to 1600A, all four-pole with 30kA breaking capacity and automatic transfer mode. For DIN-rail PC-class ATS up to 63A, see G2R-63 II; for motorised changeover, see ATS-M. Rated operational voltage, controller functions and transfer time must be confirmed before ordering.

Principais recursos

  • Eleven frame sizes from 63A to 1600A
  • CB class: changeover with built-in overcurrent protection
  • Four-pole construction for three-phase four-wire systems
  • 30kA breaking capacity listed by the supplier

Modelos / Configurações disponíveis

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Referência RITOKSFrame / rated currentPólosCapacidade de rupturaClass
RTX-ATSC-63/4P63A4P30kACB
RTX-ATSC-100/4P100A4P30kACB
RTX-ATSC-125/4P125A4P30kACB
RTX-ATSC-160/4P160A4P30kACB
RTX-ATSC-250/4P250A4P30kACB
RTX-ATSC-400/4P400A4P30kACB
RTX-ATSC-630/4P630A4P30kACB
RTX-ATSC-800/4P800A4P30kACB
RTX-ATSC-1000/4P1000A4P30kACB
RTX-ATSC-1250/4P1250A4P30kACB
RTX-ATSC-1600/4P1600A4P30kACB

Especificações Técnicas

Tipo de produtoCB-class dual-power automatic transfer switch
Corrente nominal63, 100, 125, 160, 250, 400, 630, 800, 1000, 1250 or 1600A
Pólos4P
Capacidade de ruptura30kA (supplier-listed)
Control modeAutomatic transfer
Tensão nominal de operaçãoConfirm with RITOKS before ordering
Transfer time and controller functionsConfirm with RITOKS before ordering
Dimensions and weight by frameConfirm with RITOKS before ordering

Aplicações

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a CB-class automatic transfer switch installed in a building backup power distribution board

Building backup power

Transfer critical floors or lifts from mains to a standby generator during an outage.

Hospitals and data rooms

Keep essential loads supplied by switching to the second source automatically.

Industrial plants

Change over the main distribution board between two utility feeders.

Informações a serem confirmadas para a seleção

  • Load current and frame size
  • Source types: mains, generator or second feeder
  • Rated voltage and required transfer behaviour
  • Quantidade

Perguntas frequentes

What is the difference between CB-class and PC-class ATS?

A CB-class ATS uses circuit breakers, so it also trips on overload or short circuit. A PC-class ATS only switches and needs separate upstream protection.

Which frame size do I need?

Choose a frame at or above the maximum load current. RTX-ATSC is available from 63A to 1600A; send the load current and RITOKS will confirm the frame.

Solicite um orçamento

Envie o modelo exato, as potências necessárias, a quantidade e o destino. Confirmaremos a disponibilidade e a documentação antes de elaborar o orçamento.

Solicitar informações sobre o produto e preços

Envie os números dos modelos, as especificações, as quantidades e os detalhes do destino. Confirmaremos a disponibilidade antes de elaborar uma cotação.

Voltar ao topo