Automatic Transfer Switches · RTX-ATSC
RTX-ATSC CB-Class Automatic Transfer Switches 63A-1600A, 4P
Four-pole CB-class dual-power automatic transfer switches from 63A to 1600A with 30kA breaking capacity, for automatic changeover between mains and backup supply.
Номінальний струм63A–1600A
Поляки4P
ClassCB
Руйнівна здатність30kA
Огляд продукту
RTX-ATSC transfers a load automatically between two power sources, such as mains and a generator. As a CB-class transfer switch it is built from two circuit breakers with an interlocked operating mechanism, so it switches between sources and also provides overcurrent protection. The supplier lists eleven frame sizes from 63A to 1600A, all four-pole with 30kA breaking capacity and automatic transfer mode. For DIN-rail PC-class ATS up to 63A, see G2R-63 II; for motorised changeover, see ATS-M. Rated operational voltage, controller functions and transfer time must be confirmed before ordering.
Основні особливості
- Eleven frame sizes from 63A to 1600A
- CB class: changeover with built-in overcurrent protection
- Four-pole construction for three-phase four-wire systems
- 30kA breaking capacity listed by the supplier
Доступні моделі / конфігурації
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Довідка RITOKS | Frame / rated current | Поляки | Руйнівна здатність | Class |
|---|---|---|---|---|
| RTX-ATSC-63/4P | 63A | 4P | 30kA | CB |
| RTX-ATSC-100/4P | 100 А | 4P | 30kA | CB |
| RTX-ATSC-125/4P | 125A | 4P | 30kA | CB |
| RTX-ATSC-160/4P | 160A | 4P | 30kA | CB |
| RTX-ATSC-250/4P | 250 А | 4P | 30kA | CB |
| RTX-ATSC-400/4P | 400 А | 4P | 30kA | CB |
| RTX-ATSC-630/4P | 630A | 4P | 30kA | CB |
| RTX-ATSC-800/4P | 800 А | 4P | 30kA | CB |
| RTX-ATSC-1000/4P | 1000 А | 4P | 30kA | CB |
| RTX-ATSC-1250/4P | 1250A | 4P | 30kA | CB |
| RTX-ATSC-1600/4P | 1600A | 4P | 30kA | CB |
Технічні характеристики
| Тип товару | CB-class dual-power automatic transfer switch |
|---|---|
| Номінальний струм | 63, 100, 125, 160, 250, 400, 630, 800, 1000, 1250 or 1600A |
| Поляки | 4P |
| Руйнівна здатність | 30kA (supplier-listed) |
| Control mode | Automatic transfer |
| Номінальна робоча напруга | Confirm with RITOKS before ordering |
| Transfer time and controller functions | Confirm with RITOKS before ordering |
| Dimensions and weight by frame | Confirm with RITOKS before ordering |
Застосування
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Building backup power
Transfer critical floors or lifts from mains to a standby generator during an outage.
Hospitals and data rooms
Keep essential loads supplied by switching to the second source automatically.
Industrial plants
Change over the main distribution board between two utility feeders.
Інформація, яку необхідно підтвердити для відбору
- Load current and frame size
- Source types: mains, generator or second feeder
- Rated voltage and required transfer behaviour
- Кількість
Часті запитання
What is the difference between CB-class and PC-class ATS?
A CB-class ATS uses circuit breakers, so it also trips on overload or short circuit. A PC-class ATS only switches and needs separate upstream protection.
Which frame size do I need?
Choose a frame at or above the maximum load current. RTX-ATSC is available from 63A to 1600A; send the load current and RITOKS will confirm the frame.
Замовити розрахунок вартості
Надішліть точну модель, необхідні технічні характеристики, кількість та місце призначення. Перед наданням комерційної пропозиції ми перевіримо наявність товару та необхідні документи.