Industrial Power Switching · RTX-TOR36

RTX-TOR36 Thermal Overload Relays 1A-160A

Adjustable thermal overload relays for three-phase motor protection, with 13 setting bands from 1A to 160A across three frame sizes.

Setting range1A–160A, 13 bands

НапряжениеUp to 690V

НастройкаFrame mapping to confirm

СертификацияCCC

Обзор продукта

RTX-TOR36 relays pair with contactors to trip a motor circuit on sustained overload. Each band has an adjustable current dial. Choose the band so the motor full-load current sits within the setting range.

Основные особенности

  • 13 adjustable current bands
  • Frame mapping confirmed at order
  • Rated up to 690V
  • CCC supplier-listed

Доступные модели / конфигурации

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Справочник RITOKSSetting rangeНастройка
RTX-TOR36-1-161–1.6 AConfirm with RITOKS before ordering
RTX-TOR36-15-241.5–2.4 AConfirm with RITOKS before ordering
RTX-TOR36-22-352.2–3.5 AConfirm with RITOKS before ordering
RTX-TOR36-32-53.2–5 AConfirm with RITOKS before ordering
RTX-TOR36-45-724.5–7.2 AConfirm with RITOKS before ordering
RTX-TOR36-68-116.8–11 AConfirm with RITOKS before ordering
RTX-TOR36-10-1610–16 AConfirm with RITOKS before ordering
RTX-TOR36-14-2214–22 AConfirm with RITOKS before ordering
RTX-TOR36-28-4528–45 AConfirm with RITOKS before ordering
RTX-TOR36-40-6340–63 AConfirm with RITOKS before ordering
RTX-TOR36-53-8553–85 AConfirm with RITOKS before ordering
RTX-TOR36-75-12075–120 AConfirm with RITOKS before ordering
RTX-TOR36-100-160100–160 AConfirm with RITOKS before ordering

Технические характеристики

Тип продуктаРеле тепловой перегрузки
Setting bands1–1.6, 1.5–2.4, 2.2–3.5, 3.2–5, 4.5–7.2, 6.8–11, 10–16, 14–22, 28–45, 40–63, 53–85, 75–120, 100–160 A
Frame mappingNot published; confirm with ritoks before ordering
Номинальное напряжениеUp to 690V
СертификацияCCC (supplier-listed)
Trip class and auxiliary contactsNot published; confirm with ritoks before ordering

Приложения

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician adjusting a thermal overload relay below a contactor

Motor starter panels

Combine with an AC contactor to build direct-on-line starters.

Compressor and pump motors

Protect three-phase motors against sustained overload.

Conveyor drives

Set the dial to motor full-load current on each conveyor drive.

Информация, которую необходимо подтвердить для отбора

  • Ток двигателя при полной нагрузке
  • Contactor model and mounting
  • Trip class and reset mode
  • Auxiliary contact and quantity needs

Часто задаваемые вопросы

How do I choose a setting band?

Choose a band whose range contains the motor full-load current, then set the dial to that value.

Which contactors does it fit?

Mounting compatibility is not published. Confirm the contactor model before ordering.

Запросить расценки

Укажите точную модель, требуемые технические характеристики, количество и пункт назначения. Перед составлением коммерческого предложения мы подтвердим наличие товара и необходимые документы.

Запросить информацию о продукте и цены

Сообщите номера моделей, технические характеристики, количество и данные о месте назначения. Мы проверим наличие товара перед составлением коммерческого предложения.

Вернуться в начало страницы