Current Shunts · RTX-FL15
RTX-FL15 US-Style DC Current Shunts 5A-600A, 50/75/100mV
US-style DC current shunts from 5A to 600A, each available with 50mV, 75mV or 100mV output and ±0.25% resistance tolerance.
Märkström5A–600A
Utdata50 / 75 / 100mV
Tolerance±0.25%
Ratings14 current ratings
Produktöversikt
RTX-FL15 shunts convert DC current into a low millivolt signal for panel meters, battery monitors and data loggers. Each current rating is offered at three full-scale outputs, so the shunt can match the input range of the meter instead of the meter being chosen around the shunt. Resistance follows Ohm's law, for example 0.75mΩ for 100A at 75mV.
Viktiga funktioner
- Fourteen ratings from 5A to 600A
- 50mV, 75mV and 100mV outputs for each rating
- ±0.25% resistance tolerance
- US-style shunt construction
Tillgängliga modeller / konfigurationer
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS-referens | Märkström | 50mV resistance | 75mV resistance | 100mV resistance |
|---|---|---|---|---|
| RTX-FL15-5 | 5A | 10 mΩ | 15 mΩ | 20 mΩ |
| RTX-FL15-10 | 10A | 5 mΩ | 7.5 mΩ | 10 mΩ |
| RTX-FL15-15 | 15A | 3.3333 mΩ | 5 mΩ | 6.666 mΩ |
| RTX-FL15-20 | 20A | 2.5 mΩ | 3.75 mΩ | 5 mΩ |
| RTX-FL15-30 | 30A | 1.6666 mΩ | 2.5 mΩ | 3.33 mΩ |
| RTX-FL15-50 | 50A | 1 mΩ | 1.5 mΩ | 2 mΩ |
| RTX-FL15-75 | 75A | 0.6666 mΩ | 1 mΩ | 1.33 mΩ |
| RTX-FL15-100 | 100A | 0.5 mΩ | 0.75 mΩ | 1 mΩ |
| RTX-FL15-150 | 150A | 0.333333 mΩ | 0.5 mΩ | 0.666 mΩ |
| RTX-FL15-200 | 200A | 0.25 mΩ | 0.375 mΩ | 0.5 mΩ |
| RTX-FL15-300 | 300A | 0.166667 mΩ | 0.25 mΩ | 0.333333 mΩ |
| RTX-FL15-400 | 400A | 0.125 mΩ | 0.1875 mΩ | 0.25 mΩ |
| RTX-FL15-500 | 500A | 0.1 mΩ | 0.15 mΩ | 0.2 mΩ |
| RTX-FL15-600 | 600A | 0.083333 mΩ | 0.125 mΩ | 0.166667 mΩ |
Tekniska specifikationer
| Produkttyp | DC current shunt, US-style |
|---|---|
| Märkström | 5A, 10A, 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 500A, 600A |
| Nominell effekt | 50mV, 75mV or 100mV |
| Resistance tolerance | ±0.25% |
| Motstånd | Nominal values calculated as R = V/I from rated output and current; repeating decimals are rounded. These values do not represent measured resistance or change the specified resistance tolerance |
| Continuous load derating and temperature coefficient | Confirm with RITOKS before ordering |
| Mått | Confirm with RITOKS before ordering |
Ansökningar
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Battery chargers and test benches
Measure charge and discharge current with a millivolt panel ammeter on the cabinet door.
Solar and battery monitors
Feed a battery monitor or energy meter that expects a 50mV, 75mV or 100mV shunt input.
Likströmsförsörjningar
Monitor output current of rectifiers and DC supplies in telecom and process equipment.
Uppgifter som måste bekräftas inför urvalet
- Maximum continuous DC current
- Meter or monitor input: 50mV, 75mV or 100mV
- Required accuracy and operating temperature
- Terminal and bolt size, and quantity
Vanliga frågor
How is the shunt resistance calculated?
Divide the rated output voltage by the rated current. For example 75mV divided by 100A gives 0.75mΩ.
Can a shunt run continuously at full rating?
Continuous-load derating is not published for this series. Many installations size the shunt above the normal current; confirm with RITOKS.
Begär en offert
Ange exakt modell, önskade prestandavärden, antal och leveransadress. Vi bekräftar tillgänglighet och dokumentation innan vi lämnar en offert.