Inquiry Now
RITOKS RTX-SDT shunt-input DIN rail DC current transducer on a white background

DC Current Transducers · RTX-SDT

RTX-SDT Shunt-Input DC Current Transducers, 75mV to 4-20mA/0-10V

DIN-rail DC transducers that convert a 75mV shunt signal or other DC inputs into a 4-20mA or 0-10V output with 0.5 class accuracy, for battery, PV and DC panel monitoring.

Input0–75mV shunt, mA or V

Output4–20mA / 0–10V

AccuracyClass 0.5

SupplyAC/DC 85–265V or DC24V

Product Overview

RTX-SDT transducers read the low-voltage signal from an external DC current shunt and convert it into a standard analogue signal for a PLC, meter or data logger. The supplier lists input options of DC 0–75mV for shunt measurement, as well as 0–20mA, 4–20mA, 0–5V and 0–10V, with outputs of 0–20mA, 4–20mA, 0–5V or 0–10V and class 0.5 accuracy. The auxiliary supply is AC/DC 85–265V or DC24V, the housing is about 23 × 135 × 92 mm for DIN-rail mounting and the weight is about 0.25 kg. Pair it with a 75mV shunt such as FL-2-75 or RTX-FL15. For direct inputs up to 10A or 1000V without a shunt, see RTX-DIT19. Isolation voltage, response time and operating temperature must be confirmed before ordering.

Key Features

  • DC 0–75mV input for external current shunts
  • Standard 4–20mA, 0–20mA, 0–5V or 0–10V output
  • Class 0.5 accuracy listed by the supplier
  • Narrow 23 mm DIN-rail housing with wide-range or 24V supply

Available Models / Configurations

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS referenceInput signalOutput signalAuxiliary supply
RTX-SDT-75-A4DC 0–75mV (shunt)4–20mAAC/DC 85–265V or DC24V
RTX-SDT-75-V10DC 0–75mV (shunt)0–10VAC/DC 85–265V or DC24V
RTX-SDT-75-V5DC 0–75mV (shunt)0–5VAC/DC 85–265V or DC24V
RTX-SDT-MA-A4DC 0–20mA / 4–20mA4–20mAAC/DC 85–265V or DC24V
RTX-SDT-V-A4DC 0–5V / 0–10V4–20mAAC/DC 85–265V or DC24V

Technical Specifications

Product typeDC current / signal transducer
Input signalDC 0–75mV, 0–20mA, 4–20mA, 0–5V or 0–10V
Output signalDC 0–20mA, 4–20mA, 0–5V or 0–10V
Accuracy class0.5
Auxiliary supplyAC/DC 85–265V or DC24V
MountingDIN rail
DimensionsApprox. 23 × 135 × 92 mm
WeightApprox. 0.25 kg (supplier-listed)
Isolation voltageConfirm with RITOKS before ordering
Response timeConfirm with RITOKS before ordering
Operating temperatureConfirm with RITOKS before ordering

Applications

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a DC shunt on a copper busbar wired to a DIN rail transducer and PLC in an energy storage cabinet

Battery energy storage cabinets

Convert the 75mV signal of a busbar shunt into 4–20mA so the BMS or PLC can log charge and discharge current.

PV and DC distribution panels

Monitor string or feeder current in DC panels where the current is already measured by a shunt.

Electrolysis and plating rectifiers

Feed rectifier output current from a high-current shunt into the process control system.

Information to Confirm for Selection

  • Shunt rating, for example 500A/75mV, and measured current range
  • Required output signal and load resistance
  • Available auxiliary supply voltage
  • Quantity and any isolation requirement

FAQ

Do I need a shunt with RTX-SDT?

Yes, for current measurement. RTX-SDT reads the 75mV signal of an external shunt, so the shunt sets the current range. For example, a 500A/75mV shunt gives a 0–500A measurement range.

What is the difference between RTX-SDT and RTX-DIT19?

RTX-SDT works with an external shunt and suits high currents. RTX-DIT19 measures DC current up to 10A or DC voltage up to 1000V directly, without a separate shunt.

Request a Quote

Send the exact model, required ratings, quantity and destination. We will confirm availability and documentation before quotation.

Request Product Information & Pricing

Send model numbers, ratings, quantities and destination details. We will confirm availability before preparing a quotation.