Industrial Power Switching · RTX-RIO8
RS485 Relay Output Modules
Eight-channel relay-output modules controlled over RS485 using Modbus RTU. Select the documented register map and load duty before integrating with a controller.
8Relay output channels
RS485واجهة الاتصال
مودبوس RTUالبروتوكول
1,200–115,200Listed baud-rate range
نظرة عامة على المنتج
This communication-controlled module switches eight relay outputs through a Modbus RTU connection. It is distinct from an ordinary hardwired PLC relay interface. The selected source names OMRON G2R-1 relays and an isolated RS485 interface, without establishing an isolation-test voltage. Analog I/O and Ethernet features from other family pages are outside this candidate.
الميزات الرئيسية
- Eight relay-output channels
- RS485 communication with Modbus RTU
- Eight listed serial baud-rate choices
- Replaceable plug-in relays
- Supplier identifies isolated RS485 hardware
الطرازات / التكوينات المتوفرة
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Output channels | التواصل | نطاق |
|---|---|---|---|
| RTX-RIO8-R485 | 8 relay outputs | RS485 / Modbus RTU | Eight-channel relay-output configuration |
المواصفات الفنية
| العمارة | Communication-controlled relay output module |
|---|---|
| Relay output channels | 8 |
| واجهة الاتصال | RS485, supplier-described hardware isolation |
| البروتوكول | مودبوس RTU |
| Baud-rate choices | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps |
| Relay component | OMRON G2R-1, as identified by supplier |
| Service arrangement | Plug-in relay replacement listed |
التطبيقات
AI-generated conceptual application context, not a photograph of an actual installation.

Remote Auxiliary Switching
Command compatible indicators, alarms and auxiliary relay loads from a Modbus RTU controller. Verify addresses and output registers for the selected firmware.
Plant-Room Control Panels
Add relay outputs where an RS485 control network is specified. Match load ratings, field wiring and communication settings to the project.
PLC Output Expansion
Use only with a controller that supports the documented Modbus RTU exchange. Network loss and power-restoration behavior require explicit project confirmation.
المعلومات التي يجب التأكد منها عند الاختيار
- Controller model, Modbus RTU support and required register map
- Power-supply specification and selected module wiring
- Load voltage, load type, inrush and switching frequency
- RS485 addressing, baud rate, parity and termination requirements
- Communication-loss behavior, output defaults, quantity and destination
الأسئلة الشائعة
Does this candidate provide Modbus TCP or Ethernet?
Only RS485 with Modbus RTU is established for the selected candidate. TCP and Ethernet versions are separate products.
Does the eight-relay version include analog inputs and outputs?
Analog I/O appears in general family material, but is not established for this selected eight-relay output SKU.
What must be checked before commissioning?
Check supply requirements, wiring, register map, address, baud rate, parity and output behavior during power or communication loss.
اطلب عرض أسعار
يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.
Please include: Controller model, Modbus RTU support and required register map; Power-supply specification and selected module wiring; Load voltage, load type, inrush and switching frequency.