Industrial Power Switching · RTX-RIO8
RS485 Relay Output Modules
Eight-channel relay-output modules controlled over RS485 using Modbus RTU. Select the documented register map and load duty before integrating with a controller.
8Relay output channels
RS485Komunikační rozhraní
Modbus RTUProtokol
1,200–115,200Listed baud-rate range
Přehled produktů
This communication-controlled module switches eight relay outputs through a Modbus RTU connection. It is distinct from an ordinary hardwired PLC relay interface. The selected source names OMRON G2R-1 relays and an isolated RS485 interface, without establishing an isolation-test voltage. Analog I/O and Ethernet features from other family pages are outside this candidate.
Hlavní vlastnosti
- Eight relay-output channels
- RS485 communication with Modbus RTU
- Eight listed serial baud-rate choices
- Replaceable plug-in relays
- Supplier identifies isolated RS485 hardware
Dostupné modely / konfigurace
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Output channels | Komunikace | Rozsah |
|---|---|---|---|
| RTX-RIO8-R485 | 8 relay outputs | RS485 / Modbus RTU | Eight-channel relay-output configuration |
Technické parametry
| Architektura | Communication-controlled relay output module |
|---|---|
| Relay output channels | 8 |
| Komunikační rozhraní | RS485, supplier-described hardware isolation |
| Protokol | Modbus RTU |
| Baud-rate choices | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps |
| Relay component | OMRON G2R-1, as identified by supplier |
| Service arrangement | Plug-in relay replacement listed |
Aplikace
AI-generated conceptual application context, not a photograph of an actual installation.

Remote Auxiliary Switching
Command compatible indicators, alarms and auxiliary relay loads from a Modbus RTU controller. Verify addresses and output registers for the selected firmware.
Plant-Room Control Panels
Add relay outputs where an RS485 control network is specified. Match load ratings, field wiring and communication settings to the project.
PLC Output Expansion
Use only with a controller that supports the documented Modbus RTU exchange. Network loss and power-restoration behavior require explicit project confirmation.
Údaje, které je třeba ověřit pro výběr
- Controller model, Modbus RTU support and required register map
- Power-supply specification and selected module wiring
- Load voltage, load type, inrush and switching frequency
- RS485 addressing, baud rate, parity and termination requirements
- Communication-loss behavior, output defaults, quantity and destination
Často kladené otázky
Does this candidate provide Modbus TCP or Ethernet?
Only RS485 with Modbus RTU is established for the selected candidate. TCP and Ethernet versions are separate products.
Does the eight-relay version include analog inputs and outputs?
Analog I/O appears in general family material, but is not established for this selected eight-relay output SKU.
What must be checked before commissioning?
Check supply requirements, wiring, register map, address, baud rate, parity and output behavior during power or communication loss.
Požádejte o cenovou nabídku
Uveďte přesný model, požadované parametry, množství a místo určení. Před vypracováním cenové nabídky ověříme dostupnost a dokumentaci.
Please include: Controller model, Modbus RTU support and required register map; Power-supply specification and selected module wiring; Load voltage, load type, inrush and switching frequency.