Eight-channel relay-output modules controlled over RS485 using Modbus RTU. Select the documented register map and load duty before integrating with a controller.

8Relay output channels

RS485通信インターフェース

Modbus RTUプロトコル

1,200–115,200Listed baud-rate range

製品概要

This communication-controlled module switches eight relay outputs through a Modbus RTU connection. It is distinct from an ordinary hardwired PLC relay interface. The selected source names OMRON G2R-1 relays and an isolated RS485 interface, without establishing an isolation-test voltage. Analog I/O and Ethernet features from other family pages are outside this candidate.

主な特長

  • Eight relay-output channels
  • RS485 communication with Modbus RTU
  • Eight listed serial baud-rate choices
  • Replaceable plug-in relays
  • Supplier identifies isolated RS485 hardware

取り扱いモデル/構成

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceOutput channelsコミュニケーション適用範囲
RTX-RIO8-R4858 relay outputsRS485 / Modbus RTUEight-channel relay-output configuration

技術仕様

建築Communication-controlled relay output module
Relay output channels8
通信インターフェースRS485, supplier-described hardware isolation
プロトコルModbus RTU
Baud-rate choices1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps
Relay componentOMRON G2R-1, as identified by supplier
Service arrangementPlug-in relay replacement listed

用途

AI-generated conceptual application context, not a photograph of an actual installation.

AI conceptual plant-room control cabinet and pumps; not an exact installation of the relay-output board

Remote Auxiliary Switching

Command compatible indicators, alarms and auxiliary relay loads from a Modbus RTU controller. Verify addresses and output registers for the selected firmware.

Plant-Room Control Panels

Add relay outputs where an RS485 control network is specified. Match load ratings, field wiring and communication settings to the project.

PLC Output Expansion

Use only with a controller that supports the documented Modbus RTU exchange. Network loss and power-restoration behavior require explicit project confirmation.

選考の際に確認すべき情報

  • Controller model, Modbus RTU support and required register map
  • Power-supply specification and selected module wiring
  • Load voltage, load type, inrush and switching frequency
  • RS485 addressing, baud rate, parity and termination requirements
  • Communication-loss behavior, output defaults, quantity and destination

よくある質問

Does this candidate provide Modbus TCP or Ethernet?

Only RS485 with Modbus RTU is established for the selected candidate. TCP and Ethernet versions are separate products.

Does the eight-relay version include analog inputs and outputs?

Analog I/O appears in general family material, but is not established for this selected eight-relay output SKU.

What must be checked before commissioning?

Check supply requirements, wiring, register map, address, baud rate, parity and output behavior during power or communication loss.

お見積りのお申し込み

正確な型番、必要な定格、数量、および配送先をお知らせください。お見積り前に、在庫状況と必要書類について確認させていただきます。.

Please include: Controller model, Modbus RTU support and required register map; Power-supply specification and selected module wiring; Load voltage, load type, inrush and switching frequency.

製品情報および価格のお問い合わせ

型番、定格、数量、および配送先情報をお知らせください。お見積りを作成する前に、在庫状況を確認させていただきます。.