Industrial Power Switching · RTX-RIO8
RS485 Relay Output Modules
Eight-channel relay-output modules controlled over RS485 using Modbus RTU. Select the documented register map and load duty before integrating with a controller.
8Relay output channels
RS485Interfață de comunicare
Modbus RTUProtocol
1,200–115,200Listed baud-rate range
Prezentare generală a produsului
This communication-controlled module switches eight relay outputs through a Modbus RTU connection. It is distinct from an ordinary hardwired PLC relay interface. The selected source names OMRON G2R-1 relays and an isolated RS485 interface, without establishing an isolation-test voltage. Analog I/O and Ethernet features from other family pages are outside this candidate.
Caracteristici principale
- Eight relay-output channels
- RS485 communication with Modbus RTU
- Eight listed serial baud-rate choices
- Replaceable plug-in relays
- Supplier identifies isolated RS485 hardware
Modele / Configurații disponibile
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Output channels | Comunicare | Domeniu de aplicare |
|---|---|---|---|
| RTX-RIO8-R485 | 8 relay outputs | RS485 / Modbus RTU | Eight-channel relay-output configuration |
Specificații tehnice
| Arhitectură | Communication-controlled relay output module |
|---|---|
| Relay output channels | 8 |
| Interfață de comunicare | RS485, supplier-described hardware isolation |
| Protocol | Modbus RTU |
| Baud-rate choices | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps |
| Relay component | OMRON G2R-1, as identified by supplier |
| Service arrangement | Plug-in relay replacement listed |
Aplicații
AI-generated conceptual application context, not a photograph of an actual installation.

Remote Auxiliary Switching
Command compatible indicators, alarms and auxiliary relay loads from a Modbus RTU controller. Verify addresses and output registers for the selected firmware.
Plant-Room Control Panels
Add relay outputs where an RS485 control network is specified. Match load ratings, field wiring and communication settings to the project.
PLC Output Expansion
Use only with a controller that supports the documented Modbus RTU exchange. Network loss and power-restoration behavior require explicit project confirmation.
Informații care trebuie confirmate în vederea selecției
- Controller model, Modbus RTU support and required register map
- Power-supply specification and selected module wiring
- Load voltage, load type, inrush and switching frequency
- RS485 addressing, baud rate, parity and termination requirements
- Communication-loss behavior, output defaults, quantity and destination
Întrebări frecvente
Does this candidate provide Modbus TCP or Ethernet?
Only RS485 with Modbus RTU is established for the selected candidate. TCP and Ethernet versions are separate products.
Does the eight-relay version include analog inputs and outputs?
Analog I/O appears in general family material, but is not established for this selected eight-relay output SKU.
What must be checked before commissioning?
Check supply requirements, wiring, register map, address, baud rate, parity and output behavior during power or communication loss.
Solicitați o ofertă de preț
Vă rugăm să ne comunicați modelul exact, parametrii tehnici necesari, cantitatea și destinația. Vom confirma disponibilitatea și documentația înainte de a vă transmite oferta.
Please include: Controller model, Modbus RTU support and required register map; Power-supply specification and selected module wiring; Load voltage, load type, inrush and switching frequency.