Rogowski Coils · RTX-RCT1000
RTX-RCT1000 Split-Core Rogowski Coil Transducers, 4-20mA / RS485
Split-core flexible Rogowski coil with built-in signal conversion, measuring AC current up to 1kA and providing 4–20mA, 0–20mA or RS485 output, with IP55 protection.
Measuring rangeAC 0–1kA
الإخراج4–20mA / 0–20mA / RS485
الحمايةIP55
التردد50 هرتز
نظرة عامة على المنتج
RTX-RCT1000 combines a split-core flexible Rogowski coil with a signal converter, so it can connect directly to PLCs, meters or RS485 networks without a separate integrator. The coil opens to fit around existing cables and busbars without disconnecting the circuit. The supplier lists a 1kA range, 4–20mA, 0–20mA or RS485 output, IP55 protection and 50Hz operation for indoor installations. RITOKS RTX-RC300 and ZRC coils provide millivolt outputs for meters with their own integrator. Coil diameter, accuracy and supply voltage must be confirmed for each order.
الميزات الرئيسية
- Split-core flexible coil installs around live conductors
- Built-in conversion to 4–20mA, 0–20mA or RS485
- 1kA AC measuring range
- IP55 protection for indoor installations
الطرازات / التكوينات المتوفرة
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| مرجع RITOKS | Measuring range | الإخراج |
|---|---|---|
| RTX-RCT1000-A4 | AC 0–1kA | DC 4–20mA |
| RTX-RCT1000-A0 | AC 0–1kA | DC 0–20mA |
| RTX-RCT1000-R | AC 0–1kA | RS485 |
المواصفات الفنية
| نوع المنتج | Flexible Rogowski coil with signal converter |
|---|---|
| Measuring range | AC 0–1kA |
| الإخراج | DC 4–20mA, DC 0–20mA or RS485 |
| التردد المقنن | 50 هرتز |
| Protection rating | IP55 |
| Coil material | PVC / PTE (supplier-listed) |
| التركيب | Indoor |
| Coil diameter | Confirm with RITOKS before ordering |
| Accuracy and supply voltage | Confirm with RITOKS before ordering |
التطبيقات
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Energy monitoring retrofits
Clamp around existing feeder cables to add current monitoring to a BMS or PLC without shutting down the circuit.
Busbar current measurement
Wrap the flexible coil around large busbars where rigid current transformers do not fit.
Generator and switchboard monitoring
Report generator output current to a controller over RS485.
المعلومات التي يجب التأكد منها عند الاختيار
- Maximum current and conductor size or busbar dimensions
- Required output: 4–20mA, 0–20mA or RS485
- Supply voltage available on site
- Cable length and quantity
الأسئلة الشائعة
How does RTX-RCT1000 differ from RTX-RC300?
RTX-RC300 coils give a millivolt output for meters with an integrator. RTX-RCT1000 has a built-in converter giving 4–20mA, 0–20mA or RS485.
هل يمكنه قياس التيار المستمر؟
No. Rogowski coils measure AC current. For DC, use a Hall-effect transducer.
اطلب عرض أسعار
يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.