今すぐお問い合わせ
RITOKS RTX-RCT1000 split-core Rogowski coil transducer with signal converter on a white background

Rogowski Coils · RTX-RCT1000

RTX-RCT1000 Split-Core Rogowski Coil Transducers, 4-20mA / RS485

Split-core flexible Rogowski coil with built-in signal conversion, measuring AC current up to 1kA and providing 4–20mA, 0–20mA or RS485 output, with IP55 protection.

Measuring rangeAC 0–1kA

出力4–20mA / 0–20mA / RS485

保護IP55

周波数50Hz

製品概要

RTX-RCT1000 combines a split-core flexible Rogowski coil with a signal converter, so it can connect directly to PLCs, meters or RS485 networks without a separate integrator. The coil opens to fit around existing cables and busbars without disconnecting the circuit. The supplier lists a 1kA range, 4–20mA, 0–20mA or RS485 output, IP55 protection and 50Hz operation for indoor installations. RITOKS RTX-RC300 and ZRC coils provide millivolt outputs for meters with their own integrator. Coil diameter, accuracy and supply voltage must be confirmed for each order.

主な特長

  • Split-core flexible coil installs around live conductors
  • Built-in conversion to 4–20mA, 0–20mA or RS485
  • 1kA AC measuring range
  • IP55 protection for indoor installations

取り扱いモデル/構成

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS リファレンスMeasuring range出力
RTX-RCT1000-A4AC 0–1kADC 4–20mA
RTX-RCT1000-A0AC 0–1kADC 0–20mA
RTX-RCT1000-RAC 0–1kARS485

技術仕様

製品タイプFlexible Rogowski coil with signal converter
Measuring rangeAC 0–1kA
出力DC 4–20mA, DC 0–20mA or RS485
定格周波数50Hz
Protection ratingIP55
Coil materialPVC / PTE (supplier-listed)
インストールIndoor
Coil diameterConfirm with RITOKS before ordering
Accuracy and supply voltageConfirm with RITOKS before ordering

用途

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a flexible Rogowski coil clamped around a feeder cable in a switchboard

Energy monitoring retrofits

Clamp around existing feeder cables to add current monitoring to a BMS or PLC without shutting down the circuit.

Busbar current measurement

Wrap the flexible coil around large busbars where rigid current transformers do not fit.

Generator and switchboard monitoring

Report generator output current to a controller over RS485.

選考の際に確認すべき情報

  • Maximum current and conductor size or busbar dimensions
  • Required output: 4–20mA, 0–20mA or RS485
  • Supply voltage available on site
  • Cable length and quantity

よくある質問

How does RTX-RCT1000 differ from RTX-RC300?

RTX-RC300 coils give a millivolt output for meters with an integrator. RTX-RCT1000 has a built-in converter giving 4–20mA, 0–20mA or RS485.

直流電流を測定できますか?

No. Rogowski coils measure AC current. For DC, use a Hall-effect transducer.

お見積りのお申し込み

正確な型番、必要な定格、数量、および配送先をお知らせください。お見積り前に、在庫状況と必要書類について確認させていただきます。.

製品情報および価格のお問い合わせ

型番、定格、数量、および配送先情報をお知らせください。お見積りを作成する前に、在庫状況を確認させていただきます。.