Rogowski Coils · RTX-RCT1000
RTX-RCT1000 Split-Core Rogowski Coil Transducers, 4-20mA / RS485
Split-core flexible Rogowski coil with built-in signal conversion, measuring AC current up to 1kA and providing 4–20mA, 0–20mA or RS485 output, with IP55 protection.
Measuring rangeAC 0–1kA
出力4–20mA / 0–20mA / RS485
保護IP55
周波数50Hz
製品概要
RTX-RCT1000 combines a split-core flexible Rogowski coil with a signal converter, so it can connect directly to PLCs, meters or RS485 networks without a separate integrator. The coil opens to fit around existing cables and busbars without disconnecting the circuit. The supplier lists a 1kA range, 4–20mA, 0–20mA or RS485 output, IP55 protection and 50Hz operation for indoor installations. RITOKS RTX-RC300 and ZRC coils provide millivolt outputs for meters with their own integrator. Coil diameter, accuracy and supply voltage must be confirmed for each order.
主な特長
- Split-core flexible coil installs around live conductors
- Built-in conversion to 4–20mA, 0–20mA or RS485
- 1kA AC measuring range
- IP55 protection for indoor installations
取り扱いモデル/構成
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS リファレンス | Measuring range | 出力 |
|---|---|---|
| RTX-RCT1000-A4 | AC 0–1kA | DC 4–20mA |
| RTX-RCT1000-A0 | AC 0–1kA | DC 0–20mA |
| RTX-RCT1000-R | AC 0–1kA | RS485 |
技術仕様
| 製品タイプ | Flexible Rogowski coil with signal converter |
|---|---|
| Measuring range | AC 0–1kA |
| 出力 | DC 4–20mA, DC 0–20mA or RS485 |
| 定格周波数 | 50Hz |
| Protection rating | IP55 |
| Coil material | PVC / PTE (supplier-listed) |
| インストール | Indoor |
| Coil diameter | Confirm with RITOKS before ordering |
| Accuracy and supply voltage | Confirm with RITOKS before ordering |
用途
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Energy monitoring retrofits
Clamp around existing feeder cables to add current monitoring to a BMS or PLC without shutting down the circuit.
Busbar current measurement
Wrap the flexible coil around large busbars where rigid current transformers do not fit.
Generator and switchboard monitoring
Report generator output current to a controller over RS485.
選考の際に確認すべき情報
- Maximum current and conductor size or busbar dimensions
- Required output: 4–20mA, 0–20mA or RS485
- Supply voltage available on site
- Cable length and quantity
よくある質問
How does RTX-RCT1000 differ from RTX-RC300?
RTX-RC300 coils give a millivolt output for meters with an integrator. RTX-RCT1000 has a built-in converter giving 4–20mA, 0–20mA or RS485.
直流電流を測定できますか?
No. Rogowski coils measure AC current. For DC, use a Hall-effect transducer.
お見積りのお申し込み
正確な型番、必要な定格、数量、および配送先をお知らせください。お見積り前に、在庫状況と必要書類について確認させていただきます。.