Inquiry Now
RITOKS RTX-RCT1000 split-core Rogowski coil transducer with signal converter on a white background

Rogowski Coils · RTX-RCT1000

RTX-RCT1000 Split-Core Rogowski Coil Transducers, 4-20mA / RS485

Split-core flexible Rogowski coil with built-in signal conversion, measuring AC current up to 1kA and providing 4–20mA, 0–20mA or RS485 output, with IP55 protection.

Measuring rangeAC 0–1kA

Output4–20mA / 0–20mA / RS485

ProtectionIP55

Frequency50Hz

Product Overview

RTX-RCT1000 combines a split-core flexible Rogowski coil with a signal converter, so it can connect directly to PLCs, meters or RS485 networks without a separate integrator. The coil opens to fit around existing cables and busbars without disconnecting the circuit. The supplier lists a 1kA range, 4–20mA, 0–20mA or RS485 output, IP55 protection and 50Hz operation for indoor installations. RITOKS RTX-RC300 and ZRC coils provide millivolt outputs for meters with their own integrator. Coil diameter, accuracy and supply voltage must be confirmed for each order.

Key Features

  • Split-core flexible coil installs around live conductors
  • Built-in conversion to 4–20mA, 0–20mA or RS485
  • 1kA AC measuring range
  • IP55 protection for indoor installations

Available Models / Configurations

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS referenceMeasuring rangeOutput
RTX-RCT1000-A4AC 0–1kADC 4–20mA
RTX-RCT1000-A0AC 0–1kADC 0–20mA
RTX-RCT1000-RAC 0–1kARS485

Technical Specifications

Product typeFlexible Rogowski coil with signal converter
Measuring rangeAC 0–1kA
OutputDC 4–20mA, DC 0–20mA or RS485
Rated frequency50Hz
Protection ratingIP55
Coil materialPVC / PTE (supplier-listed)
InstallationIndoor
Coil diameterConfirm with RITOKS before ordering
Accuracy and supply voltageConfirm with RITOKS before ordering

Applications

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a flexible Rogowski coil clamped around a feeder cable in a switchboard

Energy monitoring retrofits

Clamp around existing feeder cables to add current monitoring to a BMS or PLC without shutting down the circuit.

Busbar current measurement

Wrap the flexible coil around large busbars where rigid current transformers do not fit.

Generator and switchboard monitoring

Report generator output current to a controller over RS485.

Information to Confirm for Selection

  • Maximum current and conductor size or busbar dimensions
  • Required output: 4–20mA, 0–20mA or RS485
  • Supply voltage available on site
  • Cable length and quantity

FAQ

How does RTX-RCT1000 differ from RTX-RC300?

RTX-RC300 coils give a millivolt output for meters with an integrator. RTX-RCT1000 has a built-in converter giving 4–20mA, 0–20mA or RS485.

Can it measure DC current?

No. Rogowski coils measure AC current. For DC, use a Hall-effect transducer.

Request a Quote

Send the exact model, required ratings, quantity and destination. We will confirm availability and documentation before quotation.

Request Product Information & Pricing

Send model numbers, ratings, quantities and destination details. We will confirm availability before preparing a quotation.

Scroll to Top