Richiedi informazioni ora
RITOKS RTX-RCT1000 split-core Rogowski coil transducer with signal converter on a white background

Rogowski Coils · RTX-RCT1000

RTX-RCT1000 Split-Core Rogowski Coil Transducers, 4-20mA / RS485

Split-core flexible Rogowski coil with built-in signal conversion, measuring AC current up to 1kA and providing 4–20mA, 0–20mA or RS485 output, with IP55 protection.

Measuring rangeAC 0–1kA

Risultato4–20mA / 0–20mA / RS485

ProtezioneIP55

Frequenza50 Hz

Panoramica del prodotto

RTX-RCT1000 combines a split-core flexible Rogowski coil with a signal converter, so it can connect directly to PLCs, meters or RS485 networks without a separate integrator. The coil opens to fit around existing cables and busbars without disconnecting the circuit. The supplier lists a 1kA range, 4–20mA, 0–20mA or RS485 output, IP55 protection and 50Hz operation for indoor installations. RITOKS RTX-RC300 and ZRC coils provide millivolt outputs for meters with their own integrator. Coil diameter, accuracy and supply voltage must be confirmed for each order.

Caratteristiche principali

  • Split-core flexible coil installs around live conductors
  • Built-in conversion to 4–20mA, 0–20mA or RS485
  • 1kA AC measuring range
  • IP55 protection for indoor installations

Modelli / Configurazioni disponibili

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Riferimento RITOKSMeasuring rangeRisultato
RTX-RCT1000-A4AC 0–1kADC 4–20mA
RTX-RCT1000-A0AC 0–1kADC 0–20mA
RTX-RCT1000-RAC 0–1kARS485

Specifiche tecniche

Tipo di prodottoFlexible Rogowski coil with signal converter
Measuring rangeAC 0–1kA
RisultatoDC 4–20mA, DC 0–20mA or RS485
Frequenza nominale50 Hz
Protection ratingIP55
Coil materialPVC / PTE (supplier-listed)
InstallazioneIndoor
Coil diameterConfirm with RITOKS before ordering
Accuracy and supply voltageConfirm with RITOKS before ordering

Applicazioni

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a flexible Rogowski coil clamped around a feeder cable in a switchboard

Energy monitoring retrofits

Clamp around existing feeder cables to add current monitoring to a BMS or PLC without shutting down the circuit.

Busbar current measurement

Wrap the flexible coil around large busbars where rigid current transformers do not fit.

Generator and switchboard monitoring

Report generator output current to a controller over RS485.

Informazioni da verificare ai fini della selezione

  • Maximum current and conductor size or busbar dimensions
  • Required output: 4–20mA, 0–20mA or RS485
  • Supply voltage available on site
  • Cable length and quantity

Domande frequenti

How does RTX-RCT1000 differ from RTX-RC300?

RTX-RC300 coils give a millivolt output for meters with an integrator. RTX-RCT1000 has a built-in converter giving 4–20mA, 0–20mA or RS485.

È in grado di misurare la corrente continua?

No. Rogowski coils measure AC current. For DC, use a Hall-effect transducer.

Richiedi un preventivo

Indicateci il modello esatto, le potenze richieste, la quantità e la destinazione. Vi confermeremo la disponibilità e la documentazione prima di inviarvi il preventivo.

Richiedi informazioni sul prodotto e sui prezzi

Inviateci i codici dei modelli, le potenze, le quantità e i dettagli sulla destinazione. Verificheremo la disponibilità prima di preparare un preventivo.

Torna all'inizio della pagina