Power Distribution Components · RTX-RDM20
RTX-RDM20 DIN-Rail DC Redundancy Modules
Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.
Dati in ingresso2 channels, 1 output
Output current20 A continuous; 30 A peak for 5 s
Voltage systems12 / 24 / 48 VDC variants
Caduta di tensione≤0.25 V max
Panoramica del prodotto
Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.
Caratteristiche principali
- 1+1 and N+1 redundancy support
- Free-air convection cooling
- Two DC OK indications and alarm relay
- TS35/7.5 or TS35/15 DIN rail mounting
Modelli / Configurazioni disponibili
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-RDM20-12 | 12 VDC system, 9–14 VDC range |
|---|---|
| RTX-RDM20-24 | 24 VDC system, 19–29 VDC range |
| RTX-RDM20-48 | 48 VDC system, 36–60 VDC range |
Specifiche tecniche
| Dati in ingresso | 2 channels, 1 output |
|---|---|
| Output current | 20 A continuous; 30 A peak for 5 s |
| Voltage systems | 12 / 24 / 48 VDC variants |
| Caduta di tensione | ≤0.25 V max |
| Efficiency | Typical 98% |
| Alarm | Two-channel DC OK and relay contact, 30 VDC / 1 A resistive |
| Temperatura | −40 to +80 °C with derating |
| Dimensioni | 32 × 125 × 100 mm (W × H × D) |
Applicazioni
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

PLC control panels
Maintain DC supply continuity across two compatible power sources.
Industrial automation
Route alarm contacts to supervisory monitoring after wiring review.
Telecom and instrumentation cabinets
Match voltage range, output current and cabinet thermal conditions.
Informazioni da verificare ai fini della selezione
- System voltage and input range
- Continuous and peak current requirements
- Alarm relay wiring and monitoring logic
- DIN rail space, ambient temperature and derating
Domande frequenti
What information is needed for a quotation?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Richiedi un preventivo
Indicateci il modello esatto, le potenze richieste, la quantità e la destinazione. Vi confermeremo la disponibilità e la documentazione prima di inviarvi il preventivo.