Zeptejte se hned
RITOKS RTX-RDM20 DIN rail DC redundancy module

Power Distribution Components · RTX-RDM20

RTX-RDM20 DIN-Rail DC Redundancy Modules

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Vstupy2 channels, 1 output

Output current20 A continuous; 30 A peak for 5 s

Voltage systems12 / 24 / 48 VDC variants

Pokles napětí≤0.25 V max

Přehled produktů

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Hlavní vlastnosti

  • 1+1 and N+1 redundancy support
  • Free-air convection cooling
  • Two DC OK indications and alarm relay
  • TS35/7.5 or TS35/15 DIN rail mounting

Dostupné modely / konfigurace

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-RDM20-1212 VDC system, 9–14 VDC range
RTX-RDM20-2424 VDC system, 19–29 VDC range
RTX-RDM20-4848 VDC system, 36–60 VDC range

Technické parametry

Vstupy2 channels, 1 output
Output current20 A continuous; 30 A peak for 5 s
Voltage systems12 / 24 / 48 VDC variants
Pokles napětí≤0.25 V max
EfficiencyTypical 98%
AlarmTwo-channel DC OK and relay contact, 30 VDC / 1 A resistive
Teplota−40 to +80 °C with derating
Rozměry32 × 125 × 100 mm (W × H × D)

Aplikace

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: DIN-rail DC redundancy module bridging two power supplies in an automation cabinet

PLC control panels

Maintain DC supply continuity across two compatible power sources.

Industrial automation

Route alarm contacts to supervisory monitoring after wiring review.

Telecom and instrumentation cabinets

Match voltage range, output current and cabinet thermal conditions.

Údaje, které je třeba ověřit pro výběr

  • System voltage and input range
  • Continuous and peak current requirements
  • Alarm relay wiring and monitoring logic
  • DIN rail space, ambient temperature and derating

Často kladené otázky

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Požádejte o cenovou nabídku

Uveďte přesný model, požadované parametry, množství a místo určení. Před vypracováním cenové nabídky ověříme dostupnost a dokumentaci.

Žádost o informace o produktu a cenách

Zašlete nám čísla modelů, výkonové parametry, počty kusů a údaje o místě určení. Před vypracováním cenové nabídky ověříme dostupnost zboží.

Přejít nahoru