RITOKS RTX-RDM20 DIN rail DC redundancy module

Power Distribution Components · RTX-RDM20

RTX-RDM20 DIN-Rail DC Redundancy Modules

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Girişler2 channels, 1 output

Output current20 A continuous; 30 A peak for 5 s

Voltage systems12 / 24 / 48 VDC variants

Gerilim düşüşü≤0.25 V max

Ürün Genel Bakışı

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Temel Özellikler

  • 1+1 and N+1 redundancy support
  • Free-air convection cooling
  • Two DC OK indications and alarm relay
  • TS35/7.5 or TS35/15 DIN rail mounting

Mevcut Modeller / Konfigürasyonlar

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-RDM20-1212 VDC system, 9–14 VDC range
RTX-RDM20-2424 VDC system, 19–29 VDC range
RTX-RDM20-4848 VDC system, 36–60 VDC range

Teknik Özellikler

Girişler2 channels, 1 output
Output current20 A continuous; 30 A peak for 5 s
Voltage systems12 / 24 / 48 VDC variants
Gerilim düşüşü≤0.25 V max
EfficiencyTypical 98%
AlarmTwo-channel DC OK and relay contact, 30 VDC / 1 A resistive
Sıcaklık−40 to +80 °C with derating
Boyutlar32 × 125 × 100 mm (W × H × D)

Başvurular

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: DIN-rail DC redundancy module bridging two power supplies in an automation cabinet

PLC control panels

Maintain DC supply continuity across two compatible power sources.

Industrial automation

Route alarm contacts to supervisory monitoring after wiring review.

Telecom and instrumentation cabinets

Match voltage range, output current and cabinet thermal conditions.

Seçim İçin Doğrulanması Gereken Bilgiler

  • System voltage and input range
  • Continuous and peak current requirements
  • Alarm relay wiring and monitoring logic
  • DIN rail space, ambient temperature and derating

Sık Sorulan Sorular

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git