Power Distribution Components · RTX-RDM20
RTX-RDM20 DIN-Rail DC Redundancy Modules
Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.
Inddata2 channels, 1 output
Output current20 A continuous; 30 A peak for 5 s
Voltage systems12 / 24 / 48 VDC variants
Spændingsfald≤0.25 V max
Produktoversigt
Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.
Vigtigste funktioner
- 1+1 and N+1 redundancy support
- Free-air convection cooling
- Two DC OK indications and alarm relay
- TS35/7.5 or TS35/15 DIN rail mounting
Tilgængelige modeller / konfigurationer
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-RDM20-12 | 12 VDC system, 9–14 VDC range |
|---|---|
| RTX-RDM20-24 | 24 VDC system, 19–29 VDC range |
| RTX-RDM20-48 | 48 VDC system, 36–60 VDC range |
Tekniske specifikationer
| Inddata | 2 channels, 1 output |
|---|---|
| Output current | 20 A continuous; 30 A peak for 5 s |
| Voltage systems | 12 / 24 / 48 VDC variants |
| Spændingsfald | ≤0.25 V max |
| Efficiency | Typical 98% |
| Alarm | Two-channel DC OK and relay contact, 30 VDC / 1 A resistive |
| Temperatur | −40 to +80 °C with derating |
| Dimensioner | 32 × 125 × 100 mm (W × H × D) |
Anvendelser
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

PLC control panels
Maintain DC supply continuity across two compatible power sources.
Industrial automation
Route alarm contacts to supervisory monitoring after wiring review.
Telecom and instrumentation cabinets
Match voltage range, output current and cabinet thermal conditions.
Oplysninger, der skal bekræftes i forbindelse med udvælgelsen
- System voltage and input range
- Continuous and peak current requirements
- Alarm relay wiring and monitoring logic
- DIN rail space, ambient temperature and derating
Ofte stillede spørgsmål
Hvilke oplysninger skal der til for at få et tilbud?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Anmod om et tilbud
Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.