Forespørg nu
RITOKS RTX-RDM20 DIN rail DC redundancy module

Power Distribution Components · RTX-RDM20

RTX-RDM20 DIN-Rail DC Redundancy Modules

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Inddata2 channels, 1 output

Output current20 A continuous; 30 A peak for 5 s

Voltage systems12 / 24 / 48 VDC variants

Spændingsfald≤0.25 V max

Produktoversigt

Two-channel DIN-rail redundancy modules support 1+1 and N+1 arrangements for 12 V, 24 V or 48 V DC systems. The RTX-RDM20 reference maps to the 20 A family; exact voltage code is selected per enquiry.

Vigtigste funktioner

  • 1+1 and N+1 redundancy support
  • Free-air convection cooling
  • Two DC OK indications and alarm relay
  • TS35/7.5 or TS35/15 DIN rail mounting

Tilgængelige modeller / konfigurationer

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-RDM20-1212 VDC system, 9–14 VDC range
RTX-RDM20-2424 VDC system, 19–29 VDC range
RTX-RDM20-4848 VDC system, 36–60 VDC range

Tekniske specifikationer

Inddata2 channels, 1 output
Output current20 A continuous; 30 A peak for 5 s
Voltage systems12 / 24 / 48 VDC variants
Spændingsfald≤0.25 V max
EfficiencyTypical 98%
AlarmTwo-channel DC OK and relay contact, 30 VDC / 1 A resistive
Temperatur−40 to +80 °C with derating
Dimensioner32 × 125 × 100 mm (W × H × D)

Anvendelser

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: DIN-rail DC redundancy module bridging two power supplies in an automation cabinet

PLC control panels

Maintain DC supply continuity across two compatible power sources.

Industrial automation

Route alarm contacts to supervisory monitoring after wiring review.

Telecom and instrumentation cabinets

Match voltage range, output current and cabinet thermal conditions.

Oplysninger, der skal bekræftes i forbindelse med udvælgelsen

  • System voltage and input range
  • Continuous and peak current requirements
  • Alarm relay wiring and monitoring logic
  • DIN rail space, ambient temperature and derating

Ofte stillede spørgsmål

Hvilke oplysninger skal der til for at få et tilbud?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Anmod om et tilbud

Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.

Anmod om produktoplysninger og priser

Send modelnumre, specifikationer, antal og oplysninger om leveringssted. Vi bekræfter, om varerne er på lager, inden vi udarbejder et tilbud.

Gå til toppen