Electrical Measurement & Monitoring · RTX-DVT
RTX-DVT Isolated DC Voltage Transducers
Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.
IndgangsområdeConfigured within 0–1000 VDC
Udskriftsindstillinger0/4–20 mA, 0–5/1–5/0–10 V
Forsyning20–30 VDC, independent supply
Nøjagtighed0.1% FS at 20 °C
Produktoversigt
Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.
Vigtigste funktioner
- Galvanically isolated DC voltage measurement
- DIN rail housing for control cabinets
- Independent 20–30 VDC supply
- Output and input configuration confirmed per enquiry
Tilgængelige modeller / konfigurationer
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-DVT-I | Configured DC input / 4–20 mA output |
|---|---|
| RTX-DVT-V | Configured DC input / 0–10 V output |
| RTX-DVT-05 | Configured DC input / 0–5 V output |
Tekniske specifikationer
| Indgangsområde | Configured within 0–1000 VDC |
|---|---|
| Udskriftsindstillinger | 0/4–20 mA, 0–5/1–5/0–10 V |
| Forsyning | 20–30 VDC, independent supply |
| Nøjagtighed | 0.1% FS at 20 °C |
| Isolation | Input-output and power isolation; confirm test ratings |
| Response | 200 ms to 90% |
| Indlæs | Current output up to 300 Ω |
| Dimensioner | 22.5 W × 99 H × 65.5 D mm; IP20 |
Anvendelser
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Battery and DC bus monitoring
Scale the transducer to the verified bus voltage and output interface.
Renewable energy cabinets
Use isolated feedback for compatible supervisory or PLC inputs.
Industrial DC drives
Confirm polarity, range, burden and control input requirements.
Oplysninger, der skal bekræftes i forbindelse med udvælgelsen
- Nominal and maximum DC input voltage
- Required analog output and receiving impedance
- Isolation, polarity and wiring arrangement
- Ambient temperature, cabinet space and documentation
Ofte stillede spørgsmål
Hvilke oplysninger skal der til for at få et tilbud?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Anmod om et tilbud
Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.