สอบถามทันที
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

ช่วงค่าที่ป้อนConfigured within 0–1000 VDC

ตัวเลือกการออกผล0/4–20 mA, 0–5/1–5/0–10 V

การจัดหา20–30 VDC, independent supply

ความแม่นยำ0.1% FS at 20 °C

ภาพรวมผลิตภัณฑ์

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

คุณสมบัติหลัก

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

รุ่น / ตัวเลือกที่มีอยู่

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

ข้อมูลทางเทคนิค

ช่วงค่าที่ป้อนConfigured within 0–1000 VDC
ตัวเลือกการออกผล0/4–20 mA, 0–5/1–5/0–10 V
การจัดหา20–30 VDC, independent supply
ความแม่นยำ0.1% FS at 20 °C
การแยกตัวInput-output and power isolation; confirm test ratings
Response200 ms to 90%
โหลดCurrent output up to 300 Ω
ขนาด22.5 W × 99 H × 65.5 D mm; IP20

การใช้งาน

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

ข้อมูลที่จำเป็นต้องตรวจสอบเพื่อยืนยันการคัดเลือก

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

คำถามที่พบบ่อย

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

ขอใบเสนอราคา

กรุณาส่งข้อมูลรุ่นที่ถูกต้อง, ค่าเรตติ้งที่ต้องการ, จำนวน และจุดหมายปลายทาง เราจะตรวจสอบความพร้อมของสินค้าและเอกสารที่เกี่ยวข้องก่อนที่จะเสนอราคา.

ขอข้อมูลผลิตภัณฑ์และราคา

กรุณาส่งหมายเลขรุ่น, ค่ากำลัง, จำนวน และรายละเอียดจุดหมายปลายทางมาให้เรา เราจะตรวจสอบความพร้อมก่อนจัดทำใบเสนอราคา.