Demander des informations dès maintenant
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Plage d'entréeConfigured within 0–1000 VDC

Options de sortie0/4–20 mA, 0–5/1–5/0–10 V

Approvisionnement20–30 VDC, independent supply

Précision0.1% FS at 20 °C

Présentation du produit

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Caractéristiques principales

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

Modèles / configurations disponibles

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

Caractéristiques techniques

Plage d'entréeConfigured within 0–1000 VDC
Options de sortie0/4–20 mA, 0–5/1–5/0–10 V
Approvisionnement20–30 VDC, independent supply
Précision0.1% FS at 20 °C
IsolementInput-output and power isolation; confirm test ratings
Response200 ms to 90%
ChargerCurrent output up to 300 Ω
Dimensions22.5 W × 99 H × 65.5 D mm; IP20

Applications

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

Informations à vérifier pour la sélection

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

FAQ

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Demander un devis

Veuillez nous indiquer le modèle exact, les puissances nominales requises, la quantité et la destination. Nous vérifierons la disponibilité et les documents nécessaires avant de vous établir un devis.

Demander des informations sur les produits et les tarifs

Veuillez nous communiquer les références des modèles, les puissances nominales, les quantités et les informations relatives à la destination. Nous vérifierons la disponibilité avant de vous établir un devis.

Retour en haut de la page