Zapytaj teraz
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Zakres wartości wejściowychConfigured within 0–1000 VDC

Opcje wyjściowe0/4–20 mA, 0–5/1–5/0–10 V

Dostawa20–30 VDC, independent supply

Dokładność0.1% FS at 20 °C

Przegląd produktów

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Najważniejsze cechy

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

Dostępne modele / konfiguracje

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

Dane techniczne

Zakres wartości wejściowychConfigured within 0–1000 VDC
Opcje wyjściowe0/4–20 mA, 0–5/1–5/0–10 V
Dostawa20–30 VDC, independent supply
Dokładność0.1% FS at 20 °C
IzolacjaInput-output and power isolation; confirm test ratings
Response200 ms to 90%
ZaładujCurrent output up to 300 Ω
Wymiary22.5 W × 99 H × 65.5 D mm; IP20

Zastosowania

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

Informacje wymagane do potwierdzenia wyboru

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

Najczęściej zadawane pytania

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Poproś o wycenę

Prosimy o podanie dokładnego modelu, wymaganych parametrów znamionowych, ilości oraz miejsca dostawy. Przed sporządzeniem oferty sprawdzimy dostępność i dokumentację.

Poproś o informacje o produkcie i cennik

Prosimy o przesłanie numerów modeli, parametrów technicznych, ilości oraz danych dotyczących miejsca dostawy. Przed sporządzeniem oferty sprawdzimy dostępność produktów.

Przejdź na górę strony