Electrical Measurement & Monitoring · RTX-DVT
RTX-DVT Isolated DC Voltage Transducers
Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.
Zakres wartości wejściowychConfigured within 0–1000 VDC
Opcje wyjściowe0/4–20 mA, 0–5/1–5/0–10 V
Dostawa20–30 VDC, independent supply
Dokładność0.1% FS at 20 °C
Przegląd produktów
Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.
Najważniejsze cechy
- Galvanically isolated DC voltage measurement
- DIN rail housing for control cabinets
- Independent 20–30 VDC supply
- Output and input configuration confirmed per enquiry
Dostępne modele / konfiguracje
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-DVT-I | Configured DC input / 4–20 mA output |
|---|---|
| RTX-DVT-V | Configured DC input / 0–10 V output |
| RTX-DVT-05 | Configured DC input / 0–5 V output |
Dane techniczne
| Zakres wartości wejściowych | Configured within 0–1000 VDC |
|---|---|
| Opcje wyjściowe | 0/4–20 mA, 0–5/1–5/0–10 V |
| Dostawa | 20–30 VDC, independent supply |
| Dokładność | 0.1% FS at 20 °C |
| Izolacja | Input-output and power isolation; confirm test ratings |
| Response | 200 ms to 90% |
| Załaduj | Current output up to 300 Ω |
| Wymiary | 22.5 W × 99 H × 65.5 D mm; IP20 |
Zastosowania
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Battery and DC bus monitoring
Scale the transducer to the verified bus voltage and output interface.
Renewable energy cabinets
Use isolated feedback for compatible supervisory or PLC inputs.
Industrial DC drives
Confirm polarity, range, burden and control input requirements.
Informacje wymagane do potwierdzenia wyboru
- Nominal and maximum DC input voltage
- Required analog output and receiving impedance
- Isolation, polarity and wiring arrangement
- Ambient temperature, cabinet space and documentation
Najczęściej zadawane pytania
What information is needed for a quotation?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Poproś o wycenę
Prosimy o podanie dokładnego modelu, wymaganych parametrów znamionowych, ilości oraz miejsca dostawy. Przed sporządzeniem oferty sprawdzimy dostępność i dokumentację.