Zeptejte se hned
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Rozsah vstupních hodnotConfigured within 0–1000 VDC

Možnosti výstupu0/4–20 mA, 0–5/1–5/0–10 V

Dodávky20–30 VDC, independent supply

Přesnost0.1% FS at 20 °C

Přehled produktů

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Hlavní vlastnosti

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

Dostupné modely / konfigurace

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

Technické parametry

Rozsah vstupních hodnotConfigured within 0–1000 VDC
Možnosti výstupu0/4–20 mA, 0–5/1–5/0–10 V
Dodávky20–30 VDC, independent supply
Přesnost0.1% FS at 20 °C
IzolaceInput-output and power isolation; confirm test ratings
Response200 ms to 90%
NačístCurrent output up to 300 Ω
Rozměry22.5 W × 99 H × 65.5 D mm; IP20

Aplikace

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

Údaje, které je třeba ověřit pro výběr

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

Často kladené otázky

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Požádejte o cenovou nabídku

Uveďte přesný model, požadované parametry, množství a místo určení. Před vypracováním cenové nabídky ověříme dostupnost a dokumentaci.

Žádost o informace o produktu a cenách

Zašlete nám čísla modelů, výkonové parametry, počty kusů a údaje o místě určení. Před vypracováním cenové nabídky ověříme dostupnost zboží.

Přejít nahoru