استفسر الآن
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

نطاق القيم المدخلةConfigured within 0–1000 VDC

خيارات الإخراج0/4–20 mA, 0–5/1–5/0–10 V

الإمداد20–30 VDC, independent supply

الدقة0.1% FS at 20 °C

نظرة عامة على المنتج

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

الميزات الرئيسية

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

الطرازات / التكوينات المتوفرة

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

المواصفات الفنية

نطاق القيم المدخلةConfigured within 0–1000 VDC
خيارات الإخراج0/4–20 mA, 0–5/1–5/0–10 V
الإمداد20–30 VDC, independent supply
الدقة0.1% FS at 20 °C
العزلةInput-output and power isolation; confirm test ratings
Response200 ms to 90%
تحميلCurrent output up to 300 Ω
الأبعاد22.5 W × 99 H × 65.5 D mm; IP20

التطبيقات

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

المعلومات التي يجب التأكد منها عند الاختيار

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

الأسئلة الشائعة

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

اطلب عرض أسعار

يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.

طلب معلومات عن المنتج والأسعار

يرجى إرسال أرقام الطرازات، والقدرات، والكميات، وتفاصيل الوجهة. وسنقوم بالتحقق من توفر المنتجات قبل إعداد عرض الأسعار.

الرجوع إلى الأعلى