Solicita información ahora
RITOKS RTX-DVT isolated DC voltage transducer

Electrical Measurement & Monitoring · RTX-DVT

RTX-DVT Isolated DC Voltage Transducers

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Rango de entradaConfigured within 0–1000 VDC

Opciones de salida0/4–20 mA, 0–5/1–5/0–10 V

Suministro20–30 VDC, independent supply

Precisión0.1% FS at 20 °C

Descripción general del producto

Isolated DC voltage transducers convert a configured 0–1000 V DC input into a selected analog output for monitoring and control systems. Confirm the input range and output code before quotation.

Características principales

  • Galvanically isolated DC voltage measurement
  • DIN rail housing for control cabinets
  • Independent 20–30 VDC supply
  • Output and input configuration confirmed per enquiry

Modelos y configuraciones disponibles

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-DVT-IConfigured DC input / 4–20 mA output
RTX-DVT-VConfigured DC input / 0–10 V output
RTX-DVT-05Configured DC input / 0–5 V output

Especificaciones técnicas

Rango de entradaConfigured within 0–1000 VDC
Opciones de salida0/4–20 mA, 0–5/1–5/0–10 V
Suministro20–30 VDC, independent supply
Precisión0.1% FS at 20 °C
AislamientoInput-output and power isolation; confirm test ratings
Response200 ms to 90%
CargarCurrent output up to 300 Ω
Dimensiones22.5 W × 99 H × 65.5 D mm; IP20

Aplicaciones

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: isolated DC voltage transducer monitoring a battery bank and DC bus inside an industrial control cabinet

Battery and DC bus monitoring

Scale the transducer to the verified bus voltage and output interface.

Renewable energy cabinets

Use isolated feedback for compatible supervisory or PLC inputs.

Industrial DC drives

Confirm polarity, range, burden and control input requirements.

Datos que hay que confirmar para la selección

  • Nominal and maximum DC input voltage
  • Required analog output and receiving impedance
  • Isolation, polarity and wiring arrangement
  • Ambient temperature, cabinet space and documentation

Preguntas frecuentes

¿Qué datos se necesitan para elaborar un presupuesto?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Solicitar un presupuesto

Indíquenos el modelo exacto, las potencias nominales requeridas, la cantidad y el destino. Le confirmaremos la disponibilidad y la documentación antes de enviarle el presupuesto.

Solicitar información sobre el producto y precios

Envíenos los números de modelo, las potencias, las cantidades y los datos del destino. Le confirmaremos la disponibilidad antes de elaborar un presupuesto.

Ir al inicio de la página