Hemen Bilgi Alın
Eight-channel RS485 relay-output board with green terminals and plug-in relays on a white background

Industrial Power Switching · RTX-RIO8

RS485 Relay Output Modules

Eight-channel relay-output modules controlled over RS485 using Modbus RTU. Select the documented register map and load duty before integrating with a controller.

8Relay output channels

RS485İletişim arayüzü

Modbus RTUProtokol

1,200–115,200Listed baud-rate range

Ürün Genel Bakışı

This communication-controlled module switches eight relay outputs through a Modbus RTU connection. It is distinct from an ordinary hardwired PLC relay interface. The selected source names OMRON G2R-1 relays and an isolated RS485 interface, without establishing an isolation-test voltage. Analog I/O and Ethernet features from other family pages are outside this candidate.

Temel Özellikler

  • Eight relay-output channels
  • RS485 communication with Modbus RTU
  • Eight listed serial baud-rate choices
  • Replaceable plug-in relays
  • Supplier identifies isolated RS485 hardware

Mevcut Modeller / Konfigürasyonlar

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceOutput channelsİletişimKapsam
RTX-RIO8-R4858 relay outputsRS485 / Modbus RTUEight-channel relay-output configuration

Teknik Özellikler

MimarlıkCommunication-controlled relay output module
Relay output channels8
İletişim arayüzüRS485, supplier-described hardware isolation
ProtokolModbus RTU
Baud-rate choices1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps
Relay componentOMRON G2R-1, as identified by supplier
Service arrangementPlug-in relay replacement listed

Başvurular

AI-generated conceptual application context, not a photograph of an actual installation.

AI conceptual plant-room control cabinet and pumps; not an exact installation of the relay-output board

Remote Auxiliary Switching

Command compatible indicators, alarms and auxiliary relay loads from a Modbus RTU controller. Verify addresses and output registers for the selected firmware.

Plant-Room Control Panels

Add relay outputs where an RS485 control network is specified. Match load ratings, field wiring and communication settings to the project.

PLC Output Expansion

Use only with a controller that supports the documented Modbus RTU exchange. Network loss and power-restoration behavior require explicit project confirmation.

Seçim İçin Doğrulanması Gereken Bilgiler

  • Controller model, Modbus RTU support and required register map
  • Power-supply specification and selected module wiring
  • Load voltage, load type, inrush and switching frequency
  • RS485 addressing, baud rate, parity and termination requirements
  • Communication-loss behavior, output defaults, quantity and destination

Sık Sorulan Sorular

Does this candidate provide Modbus TCP or Ethernet?

Only RS485 with Modbus RTU is established for the selected candidate. TCP and Ethernet versions are separate products.

Does the eight-relay version include analog inputs and outputs?

Analog I/O appears in general family material, but is not established for this selected eight-relay output SKU.

What must be checked before commissioning?

Check supply requirements, wiring, register map, address, baud rate, parity and output behavior during power or communication loss.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Please include: Controller model, Modbus RTU support and required register map; Power-supply specification and selected module wiring; Load voltage, load type, inrush and switching frequency.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git