Forespørg nu
Two RITOKS RTX-HSC blue split-core open-loop Hall current transducers on a white background

Electrical Measurement & Monitoring · RTX-HSC

RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A

Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.

RækkeviddeAC: 20–2000A; DC: 50–2000A

NøjagtighedClass 0.2 / 0.5

Window20 / 25 / 38 / 50 / 80 mm

ForsyningDC24V or DC/AC220V

Produktoversigt

RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.

Vigtigste funktioner

  • Split-core design for retrofit installation
  • AC and DC versions to 2000A
  • Class 0.2 or 0.5 accuracy
  • Optional RS485 output

Tilgængelige modeller / konfigurationer

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS-referenceMålingRangesWindow
RTX-HSC-A20AC0–20 / 30 / 50 / 100A20 mm
RTX-HSC-A25AC0–150 / 200A25 mm
RTX-HSC-A38AC0–300 / 500 / 600 / 800A38 mm
RTX-HSC-A50AC0–1000A50 mm
RTX-HSC-A80AC0–1500 / 2000A80 mm
RTX-HSC-D20DC0–50 / 100A20 mm
RTX-HSC-D25DC0–150 / 200 / 300A25 mm
RTX-HSC-D38DC0–500 / 600 / 800A38 mm
RTX-HSC-D50DC0–1000A50 mm
RTX-HSC-D80DC0–1500 / 2000A80 mm

Tekniske specifikationer

ProdukttypeSplit-core open-loop Hall current transducer
MålingAC or DC, by version
RækkeviddeAC 20–2000A; DC 50–2000A full-scale options
Accuracy class0.2 or 0.5
Frekvens20–50Hz (supplier-listed)
Window diameter20, 25, 38, 50, 80 mm
ForsyningDC24V, DC/AC220V or specified
OutputAnalog output by order; RS485 optional

Anvendelser

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician clamping a split-core Hall transducer around a copper busbar

Busbar retrofits

Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.

DC battery and PV systems

Measure DC string or battery current up to 2000A.

HVAC and lighting loads

Monitor running current of air conditioners and special light sources.

Oplysninger, der skal bekræftes i forbindelse med udvælgelsen

  • AC or DC current and full-scale range
  • Conductor size and window diameter
  • Required output signal and supply
  • Accuracy class and quantity

Ofte stillede spørgsmål

Which output signal is supplied?

The analog output is defined at order and RS485 is optional. Confirm the output before ordering.

Can I install it without disconnecting the cable?

Yes, the split core opens around the conductor; check the window size against the cable or busbar.

Anmod om et tilbud

Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.

Anmod om produktoplysninger og priser

Send modelnumre, specifikationer, antal og oplysninger om leveringssted. Vi bekræfter, om varerne er på lager, inden vi udarbejder et tilbud.

Gå til toppen