Hemen Bilgi Alın
Two RITOKS RTX-HSC blue split-core open-loop Hall current transducers on a white background

Electrical Measurement & Monitoring · RTX-HSC

RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A

Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.

AralıkAC: 20–2000A; DC: 50–2000A

DoğrulukClass 0.2 / 0.5

Window20 / 25 / 38 / 50 / 80 mm

TedarikDC24V or DC/AC220V

Ürün Genel Bakışı

RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.

Temel Özellikler

  • Split-core design for retrofit installation
  • AC and DC versions to 2000A
  • Class 0.2 or 0.5 accuracy
  • Optional RS485 output

Mevcut Modeller / Konfigürasyonlar

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS referansıÖlçümRangesWindow
RTX-HSC-A20AC0–20 / 30 / 50 / 100A20 mm
RTX-HSC-A25AC0–150 / 200A25 mm
RTX-HSC-A38AC0–300 / 500 / 600 / 800A38 mm
RTX-HSC-A50AC0–1000A50 mm
RTX-HSC-A80AC0–1500 / 2000A80 mm
RTX-HSC-D20DC0–50 / 100A20 mm
RTX-HSC-D25DC0–150 / 200 / 300A25 mm
RTX-HSC-D38DC0–500 / 600 / 800A38 mm
RTX-HSC-D50DC0–1000A50 mm
RTX-HSC-D80DC0–1500 / 2000A80 mm

Teknik Özellikler

Ürün türüSplit-core open-loop Hall current transducer
ÖlçümAC or DC, by version
AralıkAC 20–2000A; DC 50–2000A full-scale options
Accuracy class0.2 or 0.5
Frekans20–50Hz (supplier-listed)
Window diameter20, 25, 38, 50, 80 mm
TedarikDC24V, DC/AC220V or specified
ÇıktıAnalog output by order; RS485 optional

Başvurular

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician clamping a split-core Hall transducer around a copper busbar

Busbar retrofits

Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.

DC battery and PV systems

Measure DC string or battery current up to 2000A.

HVAC and lighting loads

Monitor running current of air conditioners and special light sources.

Seçim İçin Doğrulanması Gereken Bilgiler

  • AC or DC current and full-scale range
  • Conductor size and window diameter
  • Required output signal and supply
  • Accuracy class and quantity

Sık Sorulan Sorular

Which output signal is supplied?

The analog output is defined at order and RS485 is optional. Confirm the output before ordering.

Can I install it without disconnecting the cable?

Yes, the split core opens around the conductor; check the window size against the cable or busbar.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git