Electrical Measurement & Monitoring · RTX-HSC
RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A
Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.
AralıkAC: 20–2000A; DC: 50–2000A
DoğrulukClass 0.2 / 0.5
Window20 / 25 / 38 / 50 / 80 mm
TedarikDC24V or DC/AC220V
Ürün Genel Bakışı
RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.
Temel Özellikler
- Split-core design for retrofit installation
- AC and DC versions to 2000A
- Class 0.2 or 0.5 accuracy
- Optional RS485 output
Mevcut Modeller / Konfigürasyonlar
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS referansı | Ölçüm | Ranges | Window |
|---|---|---|---|
| RTX-HSC-A20 | AC | 0–20 / 30 / 50 / 100A | 20 mm |
| RTX-HSC-A25 | AC | 0–150 / 200A | 25 mm |
| RTX-HSC-A38 | AC | 0–300 / 500 / 600 / 800A | 38 mm |
| RTX-HSC-A50 | AC | 0–1000A | 50 mm |
| RTX-HSC-A80 | AC | 0–1500 / 2000A | 80 mm |
| RTX-HSC-D20 | DC | 0–50 / 100A | 20 mm |
| RTX-HSC-D25 | DC | 0–150 / 200 / 300A | 25 mm |
| RTX-HSC-D38 | DC | 0–500 / 600 / 800A | 38 mm |
| RTX-HSC-D50 | DC | 0–1000A | 50 mm |
| RTX-HSC-D80 | DC | 0–1500 / 2000A | 80 mm |
Teknik Özellikler
| Ürün türü | Split-core open-loop Hall current transducer |
|---|---|
| Ölçüm | AC or DC, by version |
| Aralık | AC 20–2000A; DC 50–2000A full-scale options |
| Accuracy class | 0.2 or 0.5 |
| Frekans | 20–50Hz (supplier-listed) |
| Window diameter | 20, 25, 38, 50, 80 mm |
| Tedarik | DC24V, DC/AC220V or specified |
| Çıktı | Analog output by order; RS485 optional |
Başvurular
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Busbar retrofits
Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.
DC battery and PV systems
Measure DC string or battery current up to 2000A.
HVAC and lighting loads
Monitor running current of air conditioners and special light sources.
Seçim İçin Doğrulanması Gereken Bilgiler
- AC or DC current and full-scale range
- Conductor size and window diameter
- Required output signal and supply
- Accuracy class and quantity
Sık Sorulan Sorular
Which output signal is supplied?
The analog output is defined at order and RS485 is optional. Confirm the output before ordering.
Can I install it without disconnecting the cable?
Yes, the split core opens around the conductor; check the window size against the cable or busbar.
Fiyat Teklifi İsteyin