Electrical Measurement & Monitoring · RTX-HSC
RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A
Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.
Phạm viAC: 20–2000A; DC: 50–2000A
Độ chính xácClass 0.2 / 0.5
Window20 / 25 / 38 / 50 / 80 mm
Nguồn cungDC24V or DC/AC220V
Tổng quan về sản phẩm
RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.
Các tính năng chính
- Split-core design for retrofit installation
- AC and DC versions to 2000A
- Class 0.2 or 0.5 accuracy
- Optional RS485 output
Các mẫu / cấu hình có sẵn
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Tham khảo RITOKS | Đo lường | Ranges | Window |
|---|---|---|---|
| RTX-HSC-A20 | AC | 0–20 / 30 / 50 / 100A | 20 mm |
| RTX-HSC-A25 | AC | 0–150 / 200A | 25 mm |
| RTX-HSC-A38 | AC | 0–300 / 500 / 600 / 800A | 38 mm |
| RTX-HSC-A50 | AC | 0–1000A | 50 mm |
| RTX-HSC-A80 | AC | 0–1500 / 2000A | 80 mm |
| RTX-HSC-D20 | DC | 0–50 / 100A | 20 mm |
| RTX-HSC-D25 | DC | 0–150 / 200 / 300A | 25 mm |
| RTX-HSC-D38 | DC | 0–500 / 600 / 800A | 38 mm |
| RTX-HSC-D50 | DC | 0–1000A | 50 mm |
| RTX-HSC-D80 | DC | 0–1500 / 2000A | 80 mm |
Thông số kỹ thuật
| Loại sản phẩm | Split-core open-loop Hall current transducer |
|---|---|
| Đo lường | AC or DC, by version |
| Phạm vi | AC 20–2000A; DC 50–2000A full-scale options |
| Accuracy class | 0.2 or 0.5 |
| Tần số | 20–50Hz (supplier-listed) |
| Window diameter | 20, 25, 38, 50, 80 mm |
| Nguồn cung | DC24V, DC/AC220V or specified |
| Kết quả | Analog output by order; RS485 optional |
Ứng dụng
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Busbar retrofits
Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.
DC battery and PV systems
Measure DC string or battery current up to 2000A.
HVAC and lighting loads
Monitor running current of air conditioners and special light sources.
Thông tin cần xác nhận để tiến hành lựa chọn
- AC or DC current and full-scale range
- Conductor size and window diameter
- Required output signal and supply
- Accuracy class and quantity
Câu hỏi thường gặp
Which output signal is supplied?
The analog output is defined at order and RS485 is optional. Confirm the output before ordering.
Can I install it without disconnecting the cable?
Yes, the split core opens around the conductor; check the window size against the cable or busbar.
Yêu cầu báo giá
Vui lòng cung cấp thông tin chính xác về mẫu sản phẩm, thông số kỹ thuật yêu cầu, số lượng và địa điểm nhận hàng. Chúng tôi sẽ xác nhận tình trạng hàng có sẵn và các thủ tục giấy tờ trước khi gửi báo giá.