
Electrical Measurement & Monitoring · RTX-HSC
RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A
Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.
ДиапазонAC: 20–2000A; DC: 50–2000A
ТочностьClass 0.2 / 0.5
Window20 / 25 / 38 / 50 / 80 mm
ПоставкаDC24V or DC/AC220V
Обзор продукта
RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.
Основные особенности
- Split-core design for retrofit installation
- AC and DC versions to 2000A
- Class 0.2 or 0.5 accuracy
- Optional RS485 output
Доступные модели / конфигурации
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Справочник RITOKS | Измерение | Ranges | Window |
|---|---|---|---|
| RTX-HSC-A20 | AC | 0–20 / 30 / 50 / 100A | 20 mm |
| RTX-HSC-A25 | AC | 0–150 / 200A | 25 mm |
| RTX-HSC-A38 | AC | 0–300 / 500 / 600 / 800A | 38 mm |
| RTX-HSC-A50 | AC | 0–1000A | 50 мм |
| RTX-HSC-A80 | AC | 0–1500 / 2000A | 80 mm |
| RTX-HSC-D20 | DC | 0–50 / 100A | 20 mm |
| RTX-HSC-D25 | DC | 0–150 / 200 / 300A | 25 mm |
| RTX-HSC-D38 | DC | 0–500 / 600 / 800A | 38 mm |
| RTX-HSC-D50 | DC | 0–1000A | 50 мм |
| RTX-HSC-D80 | DC | 0–1500 / 2000A | 80 mm |
Технические характеристики
| Тип продукта | Split-core open-loop Hall current transducer |
|---|---|
| Измерение | AC or DC, by version |
| Диапазон | AC 20–2000A; DC 50–2000A full-scale options |
| Accuracy class | 0.2 or 0.5 |
| Частота | 20–50Hz (supplier-listed) |
| Window diameter | 20, 25, 38, 50, 80 mm |
| Поставка | DC24V, DC/AC220V or specified |
| Вывод | Analog output by order; RS485 optional |
Приложения
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Busbar retrofits
Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.
DC battery and PV systems
Measure DC string or battery current up to 2000A.
HVAC and lighting loads
Monitor running current of air conditioners and special light sources.
Информация, которую необходимо подтвердить для отбора
- AC or DC current and full-scale range
- Conductor size and window diameter
- Required output signal and supply
- Accuracy class and quantity
Часто задаваемые вопросы
Which output signal is supplied?
The analog output is defined at order and RS485 is optional. Confirm the output before ordering.
Can I install it without disconnecting the cable?
Yes, the split core opens around the conductor; check the window size against the cable or busbar.
Запросить расценки
Укажите точную модель, требуемые технические характеристики, количество и пункт назначения. Перед составлением коммерческого предложения мы подтвердим наличие товара и необходимые документы.

