지금 문의하기
Two RITOKS RTX-HSC blue split-core open-loop Hall current transducers on a white background

Electrical Measurement & Monitoring · RTX-HSC

RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A

Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.

범위AC: 20–2000A; DC: 50–2000A

정확도Class 0.2 / 0.5

Window20 / 25 / 38 / 50 / 80 mm

공급DC24V or DC/AC220V

제품 개요

RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.

주요 기능

  • Split-core design for retrofit installation
  • AC and DC versions to 2000A
  • Class 0.2 or 0.5 accuracy
  • Optional RS485 output

사용 가능한 모델 / 구성

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS 참조측정RangesWindow
RTX-HSC-A20AC0–20 / 30 / 50 / 100A20 mm
RTX-HSC-A25AC0–150 / 200A25 mm
RTX-HSC-A38AC0–300 / 500 / 600 / 800A38 mm
RTX-HSC-A50AC0–1000A50 mm
RTX-HSC-A80AC0–1500 / 2000A80 mm
RTX-HSC-D20DC0–50 / 100A20 mm
RTX-HSC-D25DC0–150 / 200 / 300A25 mm
RTX-HSC-D38DC0–500 / 600 / 800A38 mm
RTX-HSC-D50DC0–1000A50 mm
RTX-HSC-D80DC0–1500 / 2000A80 mm

기술 사양

제품 유형Split-core open-loop Hall current transducer
측정AC or DC, by version
범위AC 20–2000A; DC 50–2000A full-scale options
Accuracy class0.2 or 0.5
주파수20–50Hz (supplier-listed)
Window diameter20, 25, 38, 50, 80 mm
공급DC24V, DC/AC220V or specified
출력Analog output by order; RS485 optional

응용 분야

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician clamping a split-core Hall transducer around a copper busbar

Busbar retrofits

Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.

DC battery and PV systems

Measure DC string or battery current up to 2000A.

HVAC and lighting loads

Monitor running current of air conditioners and special light sources.

선정을 위해 확인해야 할 사항

  • AC or DC current and full-scale range
  • Conductor size and window diameter
  • Required output signal and supply
  • Accuracy class and quantity

자주 묻는 질문

Which output signal is supplied?

The analog output is defined at order and RS485 is optional. Confirm the output before ordering.

Can I install it without disconnecting the cable?

Yes, the split core opens around the conductor; check the window size against the cable or busbar.

견적 요청하기

정확한 모델명, 필요한 정격, 수량 및 배송지를 알려주십시오. 견적서를 발행하기 전에 재고 현황과 필요한 서류를 확인해 드리겠습니다.

제품 정보 및 가격 문의하기

모델 번호, 정격 사양, 수량 및 배송지 정보를 보내 주십시오. 견적을 작성하기 전에 재고 여부를 확인해 드리겠습니다.

맨 위로 스크롤하기