Electrical Measurement & Monitoring · RTX-HSC
RTX-HSC Split-Core Open-Loop Hall Transducers to 2000A
Split-core open-loop Hall current transducers for AC or DC measurement up to 2000A, installed around existing conductors without disconnection.
ช่วงAC: 20–2000A; DC: 50–2000A
ความแม่นยำClass 0.2 / 0.5
Window20 / 25 / 38 / 50 / 80 mm
การจัดหาDC24V or DC/AC220V
ภาพรวมผลิตภัณฑ์
RTX-HSC transducers open around a cable or busbar and measure current with a Hall element. AC and DC versions are offered in five window sizes. An RS485 output is optional; confirm the analog output signal for your range at order.
คุณสมบัติหลัก
- Split-core design for retrofit installation
- AC and DC versions to 2000A
- Class 0.2 or 0.5 accuracy
- Optional RS485 output
รุ่น / ตัวเลือกที่มีอยู่
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| ข้อมูลอ้างอิง RITOKS | การวัด | Ranges | Window |
|---|---|---|---|
| RTX-HSC-A20 | AC | 0–20 / 30 / 50 / 100A | 20 mm |
| RTX-HSC-A25 | AC | 0–150 / 200A | 25 mm |
| RTX-HSC-A38 | AC | 0–300 / 500 / 600 / 800A | 38 mm |
| RTX-HSC-A50 | AC | 0–1000A | 50 มม. |
| RTX-HSC-A80 | AC | 0–1500 / 2000A | 80 mm |
| RTX-HSC-D20 | DC | 0–50 / 100A | 20 mm |
| RTX-HSC-D25 | DC | 0–150 / 200 / 300A | 25 mm |
| RTX-HSC-D38 | DC | 0–500 / 600 / 800A | 38 mm |
| RTX-HSC-D50 | DC | 0–1000A | 50 มม. |
| RTX-HSC-D80 | DC | 0–1500 / 2000A | 80 mm |
ข้อมูลทางเทคนิค
| ประเภทสินค้า | Split-core open-loop Hall current transducer |
|---|---|
| การวัด | AC or DC, by version |
| ช่วง | AC 20–2000A; DC 50–2000A full-scale options |
| Accuracy class | 0.2 or 0.5 |
| ความถี่ | 20–50Hz (supplier-listed) |
| Window diameter | 20, 25, 38, 50, 80 mm |
| การจัดหา | DC24V, DC/AC220V or specified |
| ผลลัพธ์ | Analog output by order; RS485 optional |
การใช้งาน
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Busbar retrofits
Install around existing busbars to add current monitoring; confirm site isolation and safety procedure.
DC battery and PV systems
Measure DC string or battery current up to 2000A.
HVAC and lighting loads
Monitor running current of air conditioners and special light sources.
ข้อมูลที่จำเป็นต้องตรวจสอบเพื่อยืนยันการคัดเลือก
- AC or DC current and full-scale range
- Conductor size and window diameter
- Required output signal and supply
- Accuracy class and quantity
คำถามที่พบบ่อย
Which output signal is supplied?
The analog output is defined at order and RS485 is optional. Confirm the output before ordering.
Can I install it without disconnecting the cable?
Yes, the split core opens around the conductor; check the window size against the cable or busbar.
ขอใบเสนอราคา
กรุณาส่งข้อมูลรุ่นที่ถูกต้อง, ค่าเรตติ้งที่ต้องการ, จำนวน และจุดหมายปลายทาง เราจะตรวจสอบความพร้อมของสินค้าและเอกสารที่เกี่ยวข้องก่อนที่จะเสนอราคา.