Electrical Measurement & Monitoring · RTX-MGW4
RTX-MGW4 Modbus RTU-to-TCP Gateways
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.
ModbusRTU → TCP
4RS485 interfaces
12–24 V DCالإمداد
سكة DINالتركيب
نظرة عامة على المنتج
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
الميزات الرئيسية
- Protocol scope: Modbus RTU to Modbus TCP variant
- RS485 interfaces: 4
- RS232 interface: 1
- USB interface: 1 OTG
- Dry-contact I/O: 3 inputs / 3 outputs
الطرازات / التكوينات المتوفرة
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | الإعدادات | Selection notes |
|---|---|---|
| RTX-MGW4-RT | RTU-to-TCP gateway | Verify supported device map and firmware |
المواصفات الفنية
| Protocol scope | Modbus RTU to Modbus TCP variant |
|---|---|
| RS485 interfaces | 4 |
| RS232 interface | 1 |
| USB interface | 1 OTG |
| Dry-contact I/O | 3 inputs / 3 outputs |
| الإمداد | 12–24 V DC |
| الأبعاد | 144 × 90 × 63.5 mm |
| درجة حرارة التشغيل | −20 to +60 °C |
التطبيقات
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms
Connect compatible RTU devices to a supervisory TCP network.
Energy Monitoring Networks
Integrate meters only after checking register maps and polling limits.
الأتمتة الصناعية
Review port assignments, network addressing and gateway configuration.
المعلومات التي يجب التأكد منها عند الاختيار
- Device protocols, register maps and intended network topology
- Number of RTU devices and required polling rate
- Power supply and cabinet dimensions
- Firmware and commissioning requirements
الأسئلة الشائعة
What information is needed for a quotation?
Device protocols, register maps and intended network topology Please include quantity and destination.
What should be confirmed before selecting a configuration?
Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
اطلب عرض أسعار
يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.
Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.