Electrical Measurement & Monitoring · RTX-MGW4

RTX-MGW4 Modbus RTU-to-TCP Gateways

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.

ModbusRTU → TCP

4RS485 interfaces

12–24 V DCTarjonta

DIN-kiskoAsennus

Tuotekatsaus

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

Tärkeimmät ominaisuudet

  • Protocol scope: Modbus RTU to Modbus TCP variant
  • RS485 interfaces: 4
  • RS232 interface: 1
  • USB interface: 1 OTG
  • Dry-contact I/O: 3 inputs / 3 outputs

Saatavilla olevat mallit / kokoonpanot

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceAsetuksetSelection notes
RTX-MGW4-RTRTU-to-TCP gatewayVerify supported device map and firmware

Tekniset tiedot

Protocol scopeModbus RTU to Modbus TCP variant
RS485 interfaces4
RS232 interface1
USB interface1 OTG
Dry-contact I/O3 inputs / 3 outputs
Tarjonta12–24 V DC
Mitat144 × 90 × 63.5 mm
Käyttölämpötila−20 to +60 °C

Sovellukset

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms — AI conceptual application illustration

Building Plant Rooms

Connect compatible RTU devices to a supervisory TCP network.

Energy Monitoring Networks

Integrate meters only after checking register maps and polling limits.

Teollisuuden automaatio

Review port assignments, network addressing and gateway configuration.

Valintaa varten vahvistettavat tiedot

  • Device protocols, register maps and intended network topology
  • Number of RTU devices and required polling rate
  • Power supply and cabinet dimensions
  • Firmware and commissioning requirements

Usein kysytyt kysymykset

What information is needed for a quotation?

Device protocols, register maps and intended network topology Please include quantity and destination.

What should be confirmed before selecting a configuration?

Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

Pyydä tarjous

Ilmoittakaa tarkka malli, vaaditut nimellisarvot, määrä ja toimituskohde. Tarkistamme saatavuuden ja asiakirjat ennen tarjouksen antamista.

Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.