Electrical Measurement & Monitoring · RTX-MGW4
RTX-MGW4 Modbus RTU-to-TCP Gateways
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.
ModbusRTU → TCP
4RS485 interfaces
12–24 V DCPasokan
Rel DINPemasangan
Gambaran Umum Produk
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Fitur Utama
- Protocol scope: Modbus RTU to Modbus TCP variant
- RS485 interfaces: 4
- RS232 interface: 1
- USB interface: 1 OTG
- Dry-contact I/O: 3 inputs / 3 outputs
Model / Konfigurasi yang Tersedia
Gunakan referensi konfigurasi ini sebagai panduan; pastikan spesifikasi yang tepat sebelum memesan.
| Panduan Konfigurasi RITOKS | Konfigurasi | Catatan seleksi |
|---|---|---|
| RTX-MGW4-RT | RTU-to-TCP gateway | Verify supported device map and firmware |
Spesifikasi Teknis
| Protocol scope | Modbus RTU to Modbus TCP variant |
|---|---|
| RS485 interfaces | 4 |
| RS232 interface | 1 |
| USB interface | 1 OTG |
| Dry-contact I/O | 3 inputs / 3 outputs |
| Pasokan | 12–24 V DC |
| Dimensi | 144 × 90 × 63.5 mm |
| Suhu pengoperasian | −20 to +60 °C |
Aplikasi
Konteks penerapan konseptual yang dihasilkan oleh AI, bukan foto instalasi yang sebenarnya. Pastikan kesesuaian peralatan dan persyaratan sirkuit untuk konfigurasi yang dipilih.

Building Plant Rooms
Connect compatible RTU devices to a supervisory TCP network.
Energy Monitoring Networks
Integrate meters only after checking register maps and polling limits.
Otomasi Industri
Review port assignments, network addressing and gateway configuration.
Informasi yang Perlu Dipastikan untuk Proses Seleksi
- Device protocols, register maps and intended network topology
- Number of RTU devices and required polling rate
- Power supply and cabinet dimensions
- Firmware and commissioning requirements
Pertanyaan yang Sering Diajukan
Informasi apa saja yang diperlukan untuk mendapatkan penawaran harga?
Device protocols, register maps and intended network topology Please include quantity and destination.
Apa saja yang perlu dipastikan sebelum memilih konfigurasi?
Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Minta Penawaran Harga
Berikan informasi mengenai model yang tepat, spesifikasi yang dibutuhkan, jumlah, dan tujuan pengiriman. Kami akan mengonfirmasi ketersediaan dan dokumen yang diperlukan sebelum memberikan penawaran harga.
Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.