Electrical Measurement & Monitoring · RTX-MGW4
RTX-MGW4 मॉडबस RTU-से-TCP गेटवे
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.
ModbusRTU → TCP
4RS485 interfaces
12–24 V DCआपूर्ति
डीआईएन रेलस्थापना
उत्पाद अवलोकन
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
मुख्य विशेषताएँ
- Protocol scope: Modbus RTU to Modbus TCP variant
- RS485 interfaces: 4
- RS232 interface: 1
- USB interface: 1 OTG
- Dry-contact I/O: 3 inputs / 3 outputs
उपलब्ध मॉडल / विन्यास
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | संरचना | Selection notes |
|---|---|---|
| RTX-MGW4-RT | RTU-to-TCP gateway | Verify supported device map and firmware |
तकनीकी विनिर्देश
| Protocol scope | Modbus RTU to Modbus TCP variant |
|---|---|
| RS485 interfaces | 4 |
| RS232 interface | 1 |
| USB interface | 1 OTG |
| Dry-contact I/O | 3 inputs / 3 outputs |
| आपूर्ति | 12–24 V DC |
| आयाम | 144 × 90 × 63.5 mm |
| संचालन तापमान | −20 to +60 °C |
आवेदन
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms
Connect compatible RTU devices to a supervisory TCP network.
Energy Monitoring Networks
Integrate meters only after checking register maps and polling limits.
औद्योगिक स्वचालन
Review port assignments, network addressing and gateway configuration.
चयन के लिए पुष्टि हेतु जानकारी
- Device protocols, register maps and intended network topology
- Number of RTU devices and required polling rate
- Power supply and cabinet dimensions
- Firmware and commissioning requirements
अक्सर पूछे जाने वाले प्रश्न
What information is needed for a quotation?
Device protocols, register maps and intended network topology Please include quantity and destination.
What should be confirmed before selecting a configuration?
Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
कोटेशन का अनुरोध करें
सटीक मॉडल, आवश्यक रेटिंग, मात्रा और गंतव्य भेजें। हम कोटेशन से पहले उपलब्धता और दस्तावेज़ीकरण की पुष्टि करेंगे।.
Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.