अभी पूछताछ करें
सफेद DIN-रेल हाउसिंग और कई टर्मिनल इंटरफेस वाला RITOKS Modbus गेटवे

Electrical Measurement & Monitoring · RTX-MGW4

RTX-MGW4 मॉडबस RTU-से-TCP गेटवे

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.

ModbusRTU → TCP

4RS485 interfaces

12–24 V DCआपूर्ति

डीआईएन रेलस्थापना

उत्पाद अवलोकन

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

मुख्य विशेषताएँ

  • Protocol scope: Modbus RTU to Modbus TCP variant
  • RS485 interfaces: 4
  • RS232 interface: 1
  • USB interface: 1 OTG
  • Dry-contact I/O: 3 inputs / 3 outputs

उपलब्ध मॉडल / विन्यास

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceसंरचनाSelection notes
RTX-MGW4-RTRTU-to-TCP gatewayVerify supported device map and firmware

तकनीकी विनिर्देश

Protocol scopeModbus RTU to Modbus TCP variant
RS485 interfaces4
RS232 interface1
USB interface1 OTG
Dry-contact I/O3 inputs / 3 outputs
आपूर्ति12–24 V DC
आयाम144 × 90 × 63.5 mm
संचालन तापमान−20 to +60 °C

आवेदन

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms — AI conceptual application illustration

Building Plant Rooms

Connect compatible RTU devices to a supervisory TCP network.

Energy Monitoring Networks

Integrate meters only after checking register maps and polling limits.

औद्योगिक स्वचालन

Review port assignments, network addressing and gateway configuration.

चयन के लिए पुष्टि हेतु जानकारी

  • Device protocols, register maps and intended network topology
  • Number of RTU devices and required polling rate
  • Power supply and cabinet dimensions
  • Firmware and commissioning requirements

अक्सर पूछे जाने वाले प्रश्न

What information is needed for a quotation?

Device protocols, register maps and intended network topology Please include quantity and destination.

What should be confirmed before selecting a configuration?

Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

कोटेशन का अनुरोध करें

सटीक मॉडल, आवश्यक रेटिंग, मात्रा और गंतव्य भेजें। हम कोटेशन से पहले उपलब्धता और दस्तावेज़ीकरण की पुष्टि करेंगे।.

Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.

उत्पाद जानकारी और मूल्य निर्धारण का अनुरोध करें

मॉडल नंबर, रेटिंग, मात्राएँ और गंतव्य विवरण भेजें। हम कोटेशन तैयार करने से पहले उपलब्धता की पुष्टि करेंगे।.

शीर्ष पर जाएँ