Electrical Measurement & Monitoring · RTX-MGW4
RTX-MGW4 Modbus RTU-to-TCP Gateways
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.
ModbusRTU → TCP
4RS485 interfaces
12–24 V DCLieferung
DIN-SchieneMontage
Produktübersicht
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Wichtigste Merkmale
- Protocol scope: Modbus RTU to Modbus TCP variant
- RS485 interfaces: 4
- RS232 interface: 1
- USB interface: 1 OTG
- Dry-contact I/O: 3 inputs / 3 outputs
Verfügbare Modelle / Konfigurationen
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Konfiguration | Selection notes |
|---|---|---|
| RTX-MGW4-RT | RTU-to-TCP gateway | Verify supported device map and firmware |
Technische Daten
| Protocol scope | Modbus RTU to Modbus TCP variant |
|---|---|
| RS485 interfaces | 4 |
| RS232 interface | 1 |
| USB interface | 1 OTG |
| Dry-contact I/O | 3 inputs / 3 outputs |
| Lieferung | 12–24 V DC |
| Abmessungen | 144 × 90 × 63.5 mm |
| Betriebstemperatur | −20 to +60 °C |
Anwendungen
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms
Connect compatible RTU devices to a supervisory TCP network.
Energy Monitoring Networks
Integrate meters only after checking register maps and polling limits.
Industrielle Automatisierung
Review port assignments, network addressing and gateway configuration.
Für die Auswahl zu bestätigende Informationen
- Device protocols, register maps and intended network topology
- Number of RTU devices and required polling rate
- Power supply and cabinet dimensions
- Firmware and commissioning requirements
Häufig gestellte Fragen
What information is needed for a quotation?
Device protocols, register maps and intended network topology Please include quantity and destination.
What should be confirmed before selecting a configuration?
Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Angebot anfordern
Bitte teilen Sie uns das genaue Modell, die erforderlichen Nennleistungen, die Menge und den Bestimmungsort mit. Wir werden vor der Angebotserstellung die Verfügbarkeit und die erforderlichen Unterlagen prüfen.
Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.