Forespørg nu
RTX-PCV40-S Cabinet Pressure Compensation Devices — representative product photograph

Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Produktoversigt

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Vigtigste funktioner

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Tilgængelige modeller / konfigurationer

Brug disse konfigurationsoplysninger som vejledning; bekræft de nøjagtige specifikationer, inden du bestiller.

RITOKS-konfigurationsvejledningKonfigurationBemærkninger til udvælgelsen
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Tekniske specifikationer

Mounting threadM40 × 1.5 with nut
DimensionerØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Anvendelser

AI-genereret konceptuel anvendelsessammenhæng, ikke et fotografi af en faktisk installation. Kontroller, at udstyret passer, og at kredsløbskravene er opfyldt for den valgte konfiguration.

Outdoor Control Cabinets — AI conceptual application illustration

Udendørs kontrolskabe

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Oplysninger, der skal bekræftes i forbindelse med udvælgelsen

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Ofte stillede spørgsmål

Hvilke oplysninger skal der til for at få et tilbud?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

Hvad bør man sikre sig, før man vælger en konfiguration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Anmod om et tilbud

Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Anmod om produktoplysninger og priser

Send modelnumre, specifikationer, antal og oplysninger om leveringssted. Vi bekræfter, om varerne er på lager, inden vi udarbejder et tilbud.

Gå til toppen