Enclosure Climate Controls · RTX-PCV40-S
RTX-PCV40-S Cabinet Pressure Compensation Devices
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.
M40 × 1.5Mounting thread
Ø60 × 37 mmOverall dimensions
NBRGasket material
−35 to +70 °CListed temperature
Produktoversigt
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Vigtigste funktioner
- Mounting thread: M40 × 1.5 with nut
- Dimensions: Ø60 × 37 mm
- Mounting depth: Approximately 16 mm
- Tightening torque: 5 Nm; published maximum 10 Nm
- Seal: NBR gasket
Tilgængelige modeller / konfigurationer
Brug disse konfigurationsoplysninger som vejledning; bekræft de nøjagtige specifikationer, inden du bestiller.
| RITOKS-konfigurationsvejledning | Konfiguration | Bemærkninger til udvælgelsen |
|---|---|---|
| RTX-PCV40-S | M40 × 1.5 | Confirm gasket, enclosure wall and installation |
Tekniske specifikationer
| Mounting thread | M40 × 1.5 with nut |
|---|---|
| Dimensioner | Ø60 × 37 mm |
| Mounting depth | Approximately 16 mm |
| Tightening torque | 5 Nm; published maximum 10 Nm |
| Seal | NBR gasket |
| Membrane | Waterproof membrane |
| Air permeability | 1200 l/h at pressure difference of at least 70 mbar |
| Temperature range | −35 to +70 °C |
Anvendelser
AI-genereret konceptuel anvendelsessammenhæng, ikke et fotografi af en faktisk installation. Kontroller, at udstyret passer, og at kredsløbskravene er opfyldt for den valgte konfiguration.

Udendørs kontrolskabe
Evaluate pressure equalization under changing outdoor conditions.
Industrial Enclosures
Coordinate membrane devices with enclosure sealing and cable entries.
Cabinet Climate Design
Consider separately selected heaters, fans and humidity controls.
Oplysninger, der skal bekræftes i forbindelse med udvælgelsen
- Enclosure volume, pressure conditions and required protection documentation
- Wall thickness, thread opening and installation clearance
- Temperature and exposure conditions
- Required quantity and gasket arrangement
Ofte stillede spørgsmål
Hvilke oplysninger skal der til for at få et tilbud?
Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.
Hvad bør man sikre sig, før man vælger en konfiguration?
Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Anmod om et tilbud
Angiv den nøjagtige model, de krævede specifikationer, mængden og leveringsstedet. Vi bekræfter tilgængelighed og dokumentation, inden vi udarbejder et tilbud.
Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.