RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Tuotekatsaus

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Tärkeimmät ominaisuudet

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Saatavilla olevat mallit / kokoonpanot

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceAsetuksetSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Tekniset tiedot

Mounting threadM40 × 1.5 with nut
MitatØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Sovellukset

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Ulkokäyttöön tarkoitetut ohjauskaapit

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Valintaa varten vahvistettavat tiedot

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Usein kysytyt kysymykset

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Pyydä tarjous

Ilmoittakaa tarkka malli, vaaditut nimellisarvot, määrä ja toimituskohde. Tarkistamme saatavuuden ja asiakirjat ennen tarjouksen antamista.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Pyydä tuotetietoja ja hintoja

Lähetä mallinumerot, nimellistehot, määrät ja toimituskohteen tiedot. Varmistamme saatavuuden ennen tarjouksen laatimista.

Vieritä sivun alkuun