Enclosure Climate Controls · RTX-PCV40-S
RTX-PCV40-S Cabinet Pressure Compensation Devices
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.
M40 × 1.5Mounting thread
Ø60 × 37 mmOverall dimensions
NBRGasket material
−35 to +70 °CListed temperature
Panoramica del prodotto
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Caratteristiche principali
- Mounting thread: M40 × 1.5 with nut
- Dimensions: Ø60 × 37 mm
- Mounting depth: Approximately 16 mm
- Tightening torque: 5 Nm; published maximum 10 Nm
- Seal: NBR gasket
Modelli / Configurazioni disponibili
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Configurazione | Selection notes |
|---|---|---|
| RTX-PCV40-S | M40 × 1.5 | Confirm gasket, enclosure wall and installation |
Specifiche tecniche
| Mounting thread | M40 × 1.5 with nut |
|---|---|
| Dimensioni | Ø60 × 37 mm |
| Mounting depth | Approximately 16 mm |
| Tightening torque | 5 Nm; published maximum 10 Nm |
| Seal | NBR gasket |
| Membrane | Waterproof membrane |
| Air permeability | 1200 l/h at pressure difference of at least 70 mbar |
| Temperature range | −35 to +70 °C |
Applicazioni
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Armadi di comando per esterni
Evaluate pressure equalization under changing outdoor conditions.
Industrial Enclosures
Coordinate membrane devices with enclosure sealing and cable entries.
Cabinet Climate Design
Consider separately selected heaters, fans and humidity controls.
Informazioni da verificare ai fini della selezione
- Enclosure volume, pressure conditions and required protection documentation
- Wall thickness, thread opening and installation clearance
- Temperature and exposure conditions
- Required quantity and gasket arrangement
Domande frequenti
What information is needed for a quotation?
Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.
What should be confirmed before selecting a configuration?
Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Richiedi un preventivo
Indicateci il modello esatto, le potenze richieste, la quantità e la destinazione. Vi confermeremo la disponibilità e la documentazione prima di inviarvi il preventivo.
Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.