Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Panoramica del prodotto

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Caratteristiche principali

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Modelli / Configurazioni disponibili

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceConfigurazioneSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Specifiche tecniche

Mounting threadM40 × 1.5 with nut
DimensioniØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Applicazioni

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Armadi di comando per esterni

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Informazioni da verificare ai fini della selezione

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Domande frequenti

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Richiedi un preventivo

Indicateci il modello esatto, le potenze richieste, la quantità e la destinazione. Vi confermeremo la disponibilità e la documentazione prima di inviarvi il preventivo.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.