
Enclosure Climate Controls · RTX-PCV40-S
RTX-PCV40-S Cabinet Pressure Compensation Devices
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.
M40 × 1.5Mounting thread
Ø60 × 37 mmOverall dimensions
NBRGasket material
−35 to +70 °CListed temperature
Ürün Genel Bakışı
Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Temel Özellikler
- Mounting thread: M40 × 1.5 with nut
- Dimensions: Ø60 × 37 mm
- Mounting depth: Approximately 16 mm
- Tightening torque: 5 Nm; published maximum 10 Nm
- Seal: NBR gasket
Mevcut Modeller / Konfigürasyonlar
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Yapılandırma | Selection notes |
|---|---|---|
| RTX-PCV40-S | M40 × 1.5 | Confirm gasket, enclosure wall and installation |
Teknik Özellikler
| Mounting thread | M40 × 1.5 with nut |
|---|---|
| Boyutlar | Ø60 × 37 mm |
| Mounting depth | Approximately 16 mm |
| Tightening torque | 5 Nm; published maximum 10 Nm |
| Seal | NBR gasket |
| Membrane | Waterproof membrane |
| Air permeability | 1200 l/h at pressure difference of at least 70 mbar |
| Temperature range | −35 to +70 °C |
Başvurular
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Dış Mekan Kontrol Dolapları
Evaluate pressure equalization under changing outdoor conditions.
Industrial Enclosures
Coordinate membrane devices with enclosure sealing and cable entries.
Cabinet Climate Design
Consider separately selected heaters, fans and humidity controls.
Seçim İçin Doğrulanması Gereken Bilgiler
- Enclosure volume, pressure conditions and required protection documentation
- Wall thickness, thread opening and installation clearance
- Temperature and exposure conditions
- Required quantity and gasket arrangement
Sık Sorulan Sorular
What information is needed for a quotation?
Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.
What should be confirmed before selecting a configuration?
Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.
Fiyat Teklifi İsteyin
Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.
Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

