RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Ürün Genel Bakışı

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Temel Özellikler

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Mevcut Modeller / Konfigürasyonlar

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceYapılandırmaSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Teknik Özellikler

Mounting threadM40 × 1.5 with nut
BoyutlarØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Başvurular

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Dış Mekan Kontrol Dolapları

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Seçim İçin Doğrulanması Gereken Bilgiler

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Sık Sorulan Sorular

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git